T1 - Validation of software for QC assessment of MTF and NPS
AU - Peppler, Walter
AU - Hong, Wei
AU - Steinhauser, Robert
AU - Whiting, Bruce
AU - Samei, Ehsan
AU - Flynn, Michael
AU - Don, Steven
AU - Corradini, Nathan
N1 - Copyright:
Copyright 2011 Elsevier B.V., All rights reserved.
PY - 2007
Y1 - 2007
N2 - Modulation transfer function (MTF), noise power spectrum (NPS), and detective quantum efficiency (DQE) are widely accepted measures of digital radiographic system performance. However the implementation of these measurement methodologies has been limited to a handful of researchers using an assortment of techniques. A prototype edge tool and easy-to-use software program, which can generate MTF, NPS, and DQE results quickly and easily in the field, have been developed. The edge tool consists of 1mm or 250 μ thick tungsten with two polished edges. Edge and NPS data were obtained and analyzed by 3 investigators using three analysis methods: Method A, the software under development for this report; Method B, code available on the web site of one of the investigators [Saunders and Samei, Med. Phys. 33, 308-319 (2006)]; and Method C, code developed by two other of the investigators [Samei and Flynn, Med Phy. 30, 608-622, (2003)]. In all cases the differences between the results using Method B and Method A were less than 1%. The differences between Method A and Method C were larger, up to 5.26%. NPS were calculated using Method A and B. The results were very close, with average errors less than 2.5% for exposures of 27.3, 9.3, and 2.7 uGy. Analysis of data for a 10 cm misalignment shows no significant error for either the 250μ or 1mm edge. The method developed gives results that correlate closely with results obtained from established methods. The software is easy-to-use and flexible in its application. The Edge Tool developed has the necessary precision to accurately determine the MTF values of the system. Further validation of NPS and DQE is ongoing.
AB - Modulation transfer function (MTF), noise power spectrum (NPS), and detective quantum efficiency (DQE) are widely accepted measures of digital radiographic system performance. However the implementation of these measurement methodologies has been limited to a handful of researchers using an assortment of techniques. A prototype edge tool and easy-to-use software program, which can generate MTF, NPS, and DQE results quickly and easily in the field, have been developed. The edge tool consists of 1mm or 250 μ thick tungsten with two polished edges. Edge and NPS data were obtained and analyzed by 3 investigators using three analysis methods: Method A, the software under development for this report; Method B, code available on the web site of one of the investigators [Saunders and Samei, Med. Phys. 33, 308-319 (2006)]; and Method C, code developed by two other of the investigators [Samei and Flynn, Med Phy. 30, 608-622, (2003)]. In all cases the differences between the results using Method B and Method A were less than 1%. The differences between Method A and Method C were larger, up to 5.26%. NPS were calculated using Method A and B. The results were very close, with average errors less than 2.5% for exposures of 27.3, 9.3, and 2.7 uGy. Analysis of data for a 10 cm misalignment shows no significant error for either the 250μ or 1mm edge. The method developed gives results that correlate closely with results obtained from established methods. The software is easy-to-use and flexible in its application. The Edge Tool developed has the necessary precision to accurately determine the MTF values of the system. Further validation of NPS and DQE is ongoing.
KW - Detective quantum efficiency (DQE)
KW - Digital radiography
KW - Edge
KW - IEC 62220
KW - Image quality
KW - Modulation transfer function (MTF)
KW - Noise power spectrum (NPS)
UR - http://www.scopus.com/inward/record.url?scp=35148873255&partnerID=8YFLogxK
U2 - 10.1117/12.713434
DO - 10.1117/12.713434
M3 - Conference contribution
AN - SCOPUS:35148873255
SN - 081946628X
SN - 9780819466280
T3 - Progress in Biomedical Optics and Imaging - Proceedings of SPIE
BT - Medical Imaging 2007
T2 - Medical Imaging 2007: Physics of Medical Imaging
Y2 - 18 February 2007 through 22 February 2007
ER -