TY - JOUR
T1 - Validating the RTOG-endorsed brachial plexus contouring atlas
T2 - An evaluation of reproducibility among patients treated by intensity-modulated radiotherapy for head-and-neck cancer
AU - Yi, Sun K.
AU - Hall, William H.
AU - Mathai, Mathew
AU - Dublin, Arthur B.
AU - Gupta, Vishal
AU - Purdy, James A.
AU - Chen, Allen M.
PY - 2012/3/1
Y1 - 2012/3/1
N2 - Purpose: To evaluate interobserver variability for contouring the brachial plexus as an organ-at-risk (OAR) and to analyze its potential dosimetric consequences in patients treated with intensity-modulated radiotherapy (IMRT) for head-and-neck cancer. Methods and Materials: Using the Radiation Therapy Oncology Group (RTOG)-endorsed brachial plexus contouring atlas, three radiation oncologists independently delineated the OAR on treatment planning computed-tomography (CT) axial scans from 5 representative patients undergoing IMRT to a prescribed dose of 70 Gy for head-and-neck cancer. Dose-volume histograms for the brachial plexus were calculated, and interobserver differences were quantified by comparing various dosimetric statistics. Qualitative analysis was performed by visually assessing the overlapping contours on a single beam's eye view. Results: Brachial plexus volumes for the 5 patients across observers were 26 cc (18-35 cc), 25 cc (21-30 cc), 29 cc (28-32 cc), 29 cc (23-38 cc), and 29 cc (23-34 cc). On qualitative analysis, minimal variability existed except at the inferolateral portion of the OAR, where slight discrepancies were noted among the physicians. Maximum doses to the brachial plexus ranged from 71.6 to 72.6 Gy, 75.2 to 75.8 Gy, 69.1 to 71.0 Gy, 76.4 to 76.9 Gy, and 70.6 to 71.4 Gy. Respective volumes receiving doses greater than 60 Gy (V60) were 8.6 to 10.9 cc, 6.2 to 8.1 cc, 8.2 to 11.6 cc, 8.3 to 10.5 cc, and 5.6 to 9.8 cc. Conclusion: The RTOG-endorsed brachial plexus atlas provides a consistent set of guidelines for contouring this OAR with essentially no learning curve. Adoption of these contouring guidelines in the clinical setting is encouraged.
AB - Purpose: To evaluate interobserver variability for contouring the brachial plexus as an organ-at-risk (OAR) and to analyze its potential dosimetric consequences in patients treated with intensity-modulated radiotherapy (IMRT) for head-and-neck cancer. Methods and Materials: Using the Radiation Therapy Oncology Group (RTOG)-endorsed brachial plexus contouring atlas, three radiation oncologists independently delineated the OAR on treatment planning computed-tomography (CT) axial scans from 5 representative patients undergoing IMRT to a prescribed dose of 70 Gy for head-and-neck cancer. Dose-volume histograms for the brachial plexus were calculated, and interobserver differences were quantified by comparing various dosimetric statistics. Qualitative analysis was performed by visually assessing the overlapping contours on a single beam's eye view. Results: Brachial plexus volumes for the 5 patients across observers were 26 cc (18-35 cc), 25 cc (21-30 cc), 29 cc (28-32 cc), 29 cc (23-38 cc), and 29 cc (23-34 cc). On qualitative analysis, minimal variability existed except at the inferolateral portion of the OAR, where slight discrepancies were noted among the physicians. Maximum doses to the brachial plexus ranged from 71.6 to 72.6 Gy, 75.2 to 75.8 Gy, 69.1 to 71.0 Gy, 76.4 to 76.9 Gy, and 70.6 to 71.4 Gy. Respective volumes receiving doses greater than 60 Gy (V60) were 8.6 to 10.9 cc, 6.2 to 8.1 cc, 8.2 to 11.6 cc, 8.3 to 10.5 cc, and 5.6 to 9.8 cc. Conclusion: The RTOG-endorsed brachial plexus atlas provides a consistent set of guidelines for contouring this OAR with essentially no learning curve. Adoption of these contouring guidelines in the clinical setting is encouraged.
KW - Brachial plexus
KW - Contouring atlas
KW - Head and neck
KW - IMRT
KW - Reproducibility
UR - http://www.scopus.com/inward/record.url?scp=84856394953&partnerID=8YFLogxK
U2 - 10.1016/j.ijrobp.2010.10.035
DO - 10.1016/j.ijrobp.2010.10.035
M3 - Article
C2 - 21536393
AN - SCOPUS:84856394953
SN - 0360-3016
VL - 82
SP - 1060
EP - 1064
JO - International Journal of Radiation Oncology Biology Physics
JF - International Journal of Radiation Oncology Biology Physics
IS - 3
ER -