Validating the Arrhythmogenic Potential of High-, Intermediate-, and Low-Risk Drugs in a Human-Induced Pluripotent Stem Cell-Derived Cardiac Microphysiological System

  • Verena Charwat
  • , Bérénice Charrez
  • , Brian A. Siemons
  • , Henrik Finsberg
  • , Karoline H. Jæger
  • , Andrew G. Edwards
  • , Nathaniel Huebsch
  • , Samuel Wall
  • , Evan Miller
  • , Aslak Tveito
  • , Kevin E. Healy

Research output: Contribution to journalArticlepeer-review

15 Scopus citations

Abstract

Evaluation of arrhythmogenic drugs is required by regulatory agencies before any new compound can obtain market approval. Despite rigorous review, cardiac disorders remain the second most common cause for safety-related market withdrawal. On the other hand, false-positive preclinical findings prohibit potentially beneficial candidates from moving forward in the development pipeline. Complex in vitro models using cardiomyocytes derived from human-induced pluripotent stem cells (hiPSC-CM) have been identified as a useful tool that allows for rapid and cost-efficient screening of proarrhythmic drug risk. Currently available hiPSC-CM models employ simple two-dimensional (2D) culture formats with limited structural and functional relevance to the human heart muscle. Here, we present the use of our 3D cardiac microphysiological system (MPS), composed of a hiPSC-derived heart micromuscle, as a platform for arrhythmia risk assessment. We employed two different hiPSC lines and tested seven drugs with known ion channel effects and known clinical risk: dofetilide and bepridil (high risk); amiodarone and terfenadine (intermediate risk); and nifedipine, mexiletine, and lidocaine (low risk). The cardiac MPS successfully predicted drug cardiotoxicity risks based on changes in action potential duration, beat waveform (i.e., shape), and occurrence of proarrhythmic events of healthy patient hiPSC lines in the absence of risk cofactors. We showcase examples where the cardiac MPS outperformed existing hiPSC-CM 2D models.

Original languageEnglish
Pages (from-to)652-667
Number of pages16
JournalACS Pharmacology and Translational Science
Volume5
Issue number8
DOIs
StatePublished - Aug 12 2022

Keywords

  • arrhythmia
  • cardiac microtissue
  • drug risk assessment
  • hiPSC-CM
  • microphysiological system
  • safety pharmacology

Fingerprint

Dive into the research topics of 'Validating the Arrhythmogenic Potential of High-, Intermediate-, and Low-Risk Drugs in a Human-Induced Pluripotent Stem Cell-Derived Cardiac Microphysiological System'. Together they form a unique fingerprint.

Cite this