TY - JOUR
T1 - Transcatheter Aortic Valve Implantation for Bioprosthetic Valve Failure
T2 - Placement of Aortic Transcatheter Valves 3 Aortic Valve-in-Valve Study
AU - Malaisrie, S. Chris
AU - Zajarias, Alan
AU - Leon, Martin B.
AU - Mack, Michael J.
AU - Pibarot, Philippe
AU - Hahn, Rebecca T.
AU - Brown, David
AU - Wong, S. Chiu
AU - Oldemeyer, J. Bradley
AU - Shang, Kan
AU - Leipsic, Jonathon
AU - Blanke, Philipp
AU - Guerrero, Mayra
N1 - Publisher Copyright:
© 2022 The Authors
PY - 2022/11
Y1 - 2022/11
N2 - Background: Transcatheter aortic valve implantation is safe and effective for high-risk patients with bioprosthetic valve failure (BVF) but has not been studied in low- and intermediate-risk patients. One year outcomes of the PARTNER 3 Aortic Valve-in-valve (AViV) Study were evaluated. Methods: This prospective, single-arm, multicenter study enrolled 100 patients from 29 sites with surgical BVF. The primary endpoint was a composite of all-cause mortality and stroke at 1 year. The key secondary outcomes included mean gradient, functional capacity, and rehospitalization (valve-related, procedure-related, or heart failure related). Results: A total of 97 patients underwent AViV with a balloon-expandable valve from 2017 to 2019. Patients were 79.4% male with a mean age of 67.1 years and Society of Thoracic Surgeons score of 2.9%. The primary endpoint occurred in 2 patients (2.1%) who had strokes; there was no mortality at 1 year. Five patients (5.2%) had valve thrombosis events, and 9 patients (9.3%) had rehospitalizations, including 2 (2.1%) for strokes, 1 (1.0%) for heart failure, and 6 (6.2%) for aortic valve reinterventions (3 explants, 3 balloon dilations, and 1 percutaneous paravalvular regurgitation closure). From baseline to 1 year, New York Heart Association class III/IV decreased from 43.3% to 4.5%, mean gradient from 39.1 ± 18.2 mm Hg to 19.7 ± 7.6 mm Hg, and ≥moderate aortic regurgitation from 41.1% to 1.1%. Conclusions: AViV with a balloon-expandable valve improved hemodynamic and functional status at 1 year and can provide an additional therapeutic option in selected low- or intermediate-risk patients with surgical BVF, although longer term follow-up is necessary.
AB - Background: Transcatheter aortic valve implantation is safe and effective for high-risk patients with bioprosthetic valve failure (BVF) but has not been studied in low- and intermediate-risk patients. One year outcomes of the PARTNER 3 Aortic Valve-in-valve (AViV) Study were evaluated. Methods: This prospective, single-arm, multicenter study enrolled 100 patients from 29 sites with surgical BVF. The primary endpoint was a composite of all-cause mortality and stroke at 1 year. The key secondary outcomes included mean gradient, functional capacity, and rehospitalization (valve-related, procedure-related, or heart failure related). Results: A total of 97 patients underwent AViV with a balloon-expandable valve from 2017 to 2019. Patients were 79.4% male with a mean age of 67.1 years and Society of Thoracic Surgeons score of 2.9%. The primary endpoint occurred in 2 patients (2.1%) who had strokes; there was no mortality at 1 year. Five patients (5.2%) had valve thrombosis events, and 9 patients (9.3%) had rehospitalizations, including 2 (2.1%) for strokes, 1 (1.0%) for heart failure, and 6 (6.2%) for aortic valve reinterventions (3 explants, 3 balloon dilations, and 1 percutaneous paravalvular regurgitation closure). From baseline to 1 year, New York Heart Association class III/IV decreased from 43.3% to 4.5%, mean gradient from 39.1 ± 18.2 mm Hg to 19.7 ± 7.6 mm Hg, and ≥moderate aortic regurgitation from 41.1% to 1.1%. Conclusions: AViV with a balloon-expandable valve improved hemodynamic and functional status at 1 year and can provide an additional therapeutic option in selected low- or intermediate-risk patients with surgical BVF, although longer term follow-up is necessary.
KW - Aortic valve replacement
KW - Bioprosthesis
KW - Regurgitation
KW - Stenosis
KW - Transcatheter
UR - http://www.scopus.com/inward/record.url?scp=85135527045&partnerID=8YFLogxK
U2 - 10.1016/j.shj.2022.100077
DO - 10.1016/j.shj.2022.100077
M3 - Article
C2 - 37288125
AN - SCOPUS:85135527045
SN - 2474-8706
VL - 6
JO - Structural Heart
JF - Structural Heart
IS - 6
M1 - 100077
ER -