TY - JOUR
T1 - The Size of Sonoporation Pores on the Cell Membrane
AU - Zhou, Yun
AU - Kumon, Ronald E.
AU - Cui, Jianmin
AU - Deng, Cheri X.
N1 - Funding Information:
This work was supported in part by the National Institutes of Health (R01CA116592 to C. X. Deng).
PY - 2009/10
Y1 - 2009/10
N2 - Sonoporation uses ultrasound (US) to generate transient nonselective pores on the cell membrane and has been exploited as a nonviral intracellular drug and gene delivery strategy. The pore size determines the size of agents that can be delivered into the cytoplasm using the technique. However, measurements of the dynamic, submicron-scale pores have not been readily available. Electron microscopy or atomic force microscopy has been used to gauge pore size but such techniques are intrinsically limited to post-US measurements that may not accurately reveal the relevant information. As previously demonstrated, changes of the transmembrane current (TMC) of a single cell under voltage clamp can be used for monitoring sonoporation in real-time. Because the TMC is related to the diffusion of ions through the pores on the membrane, it can potentially provide information of the pore size generated in sonoporation. Using Xenopus laevis oocytes as the model system, the TMC of single cells under voltage clamp was measured in real-time to assess formation of pores on the membrane in sonoporation. The cells were exposed to US (0.2 s, 0.3 MPa, 1.075 MHz) in the presence of Definity™ microbubbles. Experiments were designed to obtain the TMC corresponding to a single pore on the membrane. The size of the pores was estimated from an electro-diffusion model that relates the TMC with pore size from the ion transport through the pores on the membrane. The mean radius of single pores was determined to be 110 nm with standard deviation of 40 nm. This study reports the first results of pore size from the TMC measured using the voltage clamp technique. (E-mail: [email protected]).
AB - Sonoporation uses ultrasound (US) to generate transient nonselective pores on the cell membrane and has been exploited as a nonviral intracellular drug and gene delivery strategy. The pore size determines the size of agents that can be delivered into the cytoplasm using the technique. However, measurements of the dynamic, submicron-scale pores have not been readily available. Electron microscopy or atomic force microscopy has been used to gauge pore size but such techniques are intrinsically limited to post-US measurements that may not accurately reveal the relevant information. As previously demonstrated, changes of the transmembrane current (TMC) of a single cell under voltage clamp can be used for monitoring sonoporation in real-time. Because the TMC is related to the diffusion of ions through the pores on the membrane, it can potentially provide information of the pore size generated in sonoporation. Using Xenopus laevis oocytes as the model system, the TMC of single cells under voltage clamp was measured in real-time to assess formation of pores on the membrane in sonoporation. The cells were exposed to US (0.2 s, 0.3 MPa, 1.075 MHz) in the presence of Definity™ microbubbles. Experiments were designed to obtain the TMC corresponding to a single pore on the membrane. The size of the pores was estimated from an electro-diffusion model that relates the TMC with pore size from the ion transport through the pores on the membrane. The mean radius of single pores was determined to be 110 nm with standard deviation of 40 nm. This study reports the first results of pore size from the TMC measured using the voltage clamp technique. (E-mail: [email protected]).
UR - http://www.scopus.com/inward/record.url?scp=70349216363&partnerID=8YFLogxK
U2 - 10.1016/j.ultrasmedbio.2009.05.012
DO - 10.1016/j.ultrasmedbio.2009.05.012
M3 - Article
C2 - 19647924
AN - SCOPUS:70349216363
SN - 0301-5629
VL - 35
SP - 1756
EP - 1760
JO - Ultrasound in Medicine and Biology
JF - Ultrasound in Medicine and Biology
IS - 10
ER -