TY - JOUR
T1 - The postimplantation electrocardiogram predicts clinical response to cardiac resynchronization therapy
AU - Coverstone, Edward
AU - Sheehy, Justin
AU - Kleiger, Robert E.
AU - Smith, Timothy W.
N1 - Publisher Copyright:
© 2015 Wiley Periodicals, Inc.
PY - 2015/5/1
Y1 - 2015/5/1
N2 - Background Biventricular (BiV) pacing for cardiac resynchronization therapy (CRT) is intended to improve left ventricular function by coordinating systolic activity of the septum and free walls. Optimal resynchronization should be manifested by 12-lead electrocardiogram (ECG) patterns consistent with resynchronized activation, a tall (≥4 mm) R wave in V1, and predominant negative deflection in lead I (RV1SI). We investigated whether the presence or absence of RV1SI predicts heart failure outcomes within 1 year of CRT implant. Methods Two independent physicians reviewed the paced ECG of 213 patients post-CRT device implantation with disputes resolved by a third reviewer. The primary end points of all-cause death, unplanned hospitalization, left ventricular assist device implant, or transplant within a 1-year follow-up were blindly adjudicated according to standard definitions. Groups were compared via Kaplan-Meier estimates and Cox proportional hazards models to determine association with event-free survival. Results Among CRT patients postimplantation, 56 (26.3%) exhibited the RV1SI pattern on ECG. Patients with the RV1SI pattern were significantly less likely to achieve the primary end point as compared to patients without the RV1SI pattern (33.9% vs 52.2%; Log Rank P = 0.022). This difference was driven by a significantly lower risk for unplanned hospitalization among patients with the RV1SI pattern (hazard ratio = 0.510; confidence interval [0.298, 0.876]). The predictive value remained after adjustment for potential confounders (P = 0.004). Conclusions The 12-lead ECG postimplantation predicts clinical outcomes of BiV pacing. Such prediction may be useful in predicting the need for alternative or advanced heart failure therapies. Further study into ECG patterns may help to prospectively guide CRT.
AB - Background Biventricular (BiV) pacing for cardiac resynchronization therapy (CRT) is intended to improve left ventricular function by coordinating systolic activity of the septum and free walls. Optimal resynchronization should be manifested by 12-lead electrocardiogram (ECG) patterns consistent with resynchronized activation, a tall (≥4 mm) R wave in V1, and predominant negative deflection in lead I (RV1SI). We investigated whether the presence or absence of RV1SI predicts heart failure outcomes within 1 year of CRT implant. Methods Two independent physicians reviewed the paced ECG of 213 patients post-CRT device implantation with disputes resolved by a third reviewer. The primary end points of all-cause death, unplanned hospitalization, left ventricular assist device implant, or transplant within a 1-year follow-up were blindly adjudicated according to standard definitions. Groups were compared via Kaplan-Meier estimates and Cox proportional hazards models to determine association with event-free survival. Results Among CRT patients postimplantation, 56 (26.3%) exhibited the RV1SI pattern on ECG. Patients with the RV1SI pattern were significantly less likely to achieve the primary end point as compared to patients without the RV1SI pattern (33.9% vs 52.2%; Log Rank P = 0.022). This difference was driven by a significantly lower risk for unplanned hospitalization among patients with the RV1SI pattern (hazard ratio = 0.510; confidence interval [0.298, 0.876]). The predictive value remained after adjustment for potential confounders (P = 0.004). Conclusions The 12-lead ECG postimplantation predicts clinical outcomes of BiV pacing. Such prediction may be useful in predicting the need for alternative or advanced heart failure therapies. Further study into ECG patterns may help to prospectively guide CRT.
KW - biventricular pacing
KW - cardiac resynchronization therapy
KW - congestive heart failure
KW - electrocardiogram
UR - http://www.scopus.com/inward/record.url?scp=84928955934&partnerID=8YFLogxK
U2 - 10.1111/pace.12609
DO - 10.1111/pace.12609
M3 - Article
C2 - 25732143
AN - SCOPUS:84928955934
SN - 0147-8389
VL - 38
SP - 572
EP - 580
JO - PACE - Pacing and Clinical Electrophysiology
JF - PACE - Pacing and Clinical Electrophysiology
IS - 5
ER -