TY - JOUR
T1 - The plasma supplemented modified activated clotting time for monitoring of heparinization during cardiopulmonary bypass
T2 - A pilot investigation
AU - Koster, Andreas
AU - Despotis, George
AU - Gruendel, Marcus
AU - Fischer, Thomas
AU - Praus, Michael
AU - Kuppe, Herman
AU - Levy, Jerrold H.
PY - 2002/1/1
Y1 - 2002/1/1
N2 - The standard celite or kaolin activated clotting time (ACT) correlates poorly with heparin levels during cardiopulmonary bypass (CPB). We compared a modified kaolin ACT, in which plasma was supplemented, to a standard undiluted kaolin ACT for monitoring heparin levels during CPB. Fifteen patients undergoing normothermic CPB were enrolled in this prospective study. Heparin management was performed according to the Hepcon HMS results (Medtronic, Minneapolis, MN). The ACTs were performed with the ACT II device (Medtronic). Hepcon HMS calculations, standard kaolin ACTs, and plasma supplemented modified ACTs (mACTs), prepared by diluting blood samples 1:1 with human plasma (Behring, Marburg, Germany), were measured every 30 min during CPB. The data obtained were correlated to the plasma chromogenic anti-Xa activity as a reference assay for heparin levels. A total of 64 samples were evaluated. The chromogenic anti-Xa activity ranged from 0.2 to 5.5 IU/mL. The Hepcon HMS calculations ranged from 2.7-8.2 IU/mL of heparin, the standard ACT ranged from 424 to >999 s, and the mACT ranged from 210 to 801 s. The correlation to the chromogenic anti-Xa method was r = 0.43 for the standard kaolin ACT and r = 0.69 for the plasma mACT. The plasma mACT provided an improved correlation to chromogenically measured levels of anti-Xa activity during CPB. The improved correlation most likely results from a correction of the effects of the impairment of the coagulation system caused by hemodilution and consumption of procoagulants on extracorporeal surfaces.
AB - The standard celite or kaolin activated clotting time (ACT) correlates poorly with heparin levels during cardiopulmonary bypass (CPB). We compared a modified kaolin ACT, in which plasma was supplemented, to a standard undiluted kaolin ACT for monitoring heparin levels during CPB. Fifteen patients undergoing normothermic CPB were enrolled in this prospective study. Heparin management was performed according to the Hepcon HMS results (Medtronic, Minneapolis, MN). The ACTs were performed with the ACT II device (Medtronic). Hepcon HMS calculations, standard kaolin ACTs, and plasma supplemented modified ACTs (mACTs), prepared by diluting blood samples 1:1 with human plasma (Behring, Marburg, Germany), were measured every 30 min during CPB. The data obtained were correlated to the plasma chromogenic anti-Xa activity as a reference assay for heparin levels. A total of 64 samples were evaluated. The chromogenic anti-Xa activity ranged from 0.2 to 5.5 IU/mL. The Hepcon HMS calculations ranged from 2.7-8.2 IU/mL of heparin, the standard ACT ranged from 424 to >999 s, and the mACT ranged from 210 to 801 s. The correlation to the chromogenic anti-Xa method was r = 0.43 for the standard kaolin ACT and r = 0.69 for the plasma mACT. The plasma mACT provided an improved correlation to chromogenically measured levels of anti-Xa activity during CPB. The improved correlation most likely results from a correction of the effects of the impairment of the coagulation system caused by hemodilution and consumption of procoagulants on extracorporeal surfaces.
UR - http://www.scopus.com/inward/record.url?scp=0036297734&partnerID=8YFLogxK
U2 - 10.1097/00000539-200207000-00004
DO - 10.1097/00000539-200207000-00004
M3 - Article
C2 - 12088937
AN - SCOPUS:0036297734
SN - 0003-2999
VL - 95
SP - 26
EP - 30
JO - Anesthesia and Analgesia
JF - Anesthesia and Analgesia
IS - 1
ER -