TY - JOUR
T1 - The freedom to heal
T2 - Nonrigid immobilization by a halo orthosis Technical note
AU - Genin, Guy M.
AU - Rosenberg, Stuart P.
AU - Seger, Laura M.
AU - Tran, Elizabeth L.
AU - Rivet, Dennis J.
AU - Leuthardt, Eric C.
N1 - Publisher Copyright:
© AANS, 2014.
PY - 2014/11/1
Y1 - 2014/11/1
N2 - Halo orthoses present a paradox. On the one hand, the nominally rigid immobilization they provide to the head aims to remove loads on the cervical spine following injury or surgery, and the devices are retightened routinely to maintain this. On the other hand, bone growth and remodeling are well known to require mechanical stressing. How are these competing needs balanced? To understand this trade-off in an effective, commercial halo orthosis, the authors quantified the response of a commercial halo orthosis to physiological loading levels, applied symmetrically about the sagittal plane. They showed for the first time that after a few cycles of loading analogous to a few steps taken by a patient, the support presented by a standard commercial halo orthosis becomes nonlinear. When analyzed through straightforward structural modeling, these data revealed that the nonlinearity permits mild head motion while severely restricting larger motion. These observations are useful because they open the possibility that halo orthosis installation could be optimized to transfer mild spinal loads that support healing while blocking pathological loads.
AB - Halo orthoses present a paradox. On the one hand, the nominally rigid immobilization they provide to the head aims to remove loads on the cervical spine following injury or surgery, and the devices are retightened routinely to maintain this. On the other hand, bone growth and remodeling are well known to require mechanical stressing. How are these competing needs balanced? To understand this trade-off in an effective, commercial halo orthosis, the authors quantified the response of a commercial halo orthosis to physiological loading levels, applied symmetrically about the sagittal plane. They showed for the first time that after a few cycles of loading analogous to a few steps taken by a patient, the support presented by a standard commercial halo orthosis becomes nonlinear. When analyzed through straightforward structural modeling, these data revealed that the nonlinearity permits mild head motion while severely restricting larger motion. These observations are useful because they open the possibility that halo orthosis installation could be optimized to transfer mild spinal loads that support healing while blocking pathological loads.
KW - Halo orthosis
KW - Mechanical compliance
KW - Spinal immobilization
KW - Structural characterization
UR - http://www.scopus.com/inward/record.url?scp=84922394780&partnerID=8YFLogxK
U2 - 10.3171/2014.7.SPINE13747
DO - 10.3171/2014.7.SPINE13747
M3 - Article
C2 - 25147974
AN - SCOPUS:84922394780
SN - 1547-5654
VL - 21
SP - 811
EP - 816
JO - Journal of Neurosurgery: Spine
JF - Journal of Neurosurgery: Spine
IS - 5
ER -