TY - JOUR
T1 - The first North American use of the Pipeline Flex flow diverter
AU - Duckworth, Edward A.M.
AU - Nickele, Christopher
AU - Hoit, Daniel
AU - Belayev, Andrey
AU - Moran, Christopher J.
AU - Arthur, Adam S.
N1 - Publisher Copyright:
© 2015 BMJ Publishing Group.
Copyright:
Copyright 2016 Elsevier B.V., All rights reserved.
PY - 2015/1/30
Y1 - 2015/1/30
N2 - Flow diversion for the management of intracranial aneurysms represents a paradigm shift in how aneurysms are managed. The Pipeline embolization device (PED) is, to date, the only flow diverter approved for use in the USA by the Food and Drug Administration. Limitations and complications with new treatment strategies are inevitable, and with the PED there have been reports of complications, most commonly with challenging deployments. Once deployment has been initiated, the device is 'one-way'; it can only be deployed further or removed. Yet, situations arise in which the ability to recapture or reposition the device would be advantageous. A second-generation Pipeline has been developed that addresses these concerns. We report the first use in North America of this second-generation Pipeline device: the Pipeline Flex. We discuss our rationale for using the device, our impressions of its operation, and the relevant literature concerning the current state of flow diversion.
AB - Flow diversion for the management of intracranial aneurysms represents a paradigm shift in how aneurysms are managed. The Pipeline embolization device (PED) is, to date, the only flow diverter approved for use in the USA by the Food and Drug Administration. Limitations and complications with new treatment strategies are inevitable, and with the PED there have been reports of complications, most commonly with challenging deployments. Once deployment has been initiated, the device is 'one-way'; it can only be deployed further or removed. Yet, situations arise in which the ability to recapture or reposition the device would be advantageous. A second-generation Pipeline has been developed that addresses these concerns. We report the first use in North America of this second-generation Pipeline device: the Pipeline Flex. We discuss our rationale for using the device, our impressions of its operation, and the relevant literature concerning the current state of flow diversion.
UR - http://www.scopus.com/inward/record.url?scp=84964211319&partnerID=8YFLogxK
U2 - 10.1136/bcr-2014-011548
DO - 10.1136/bcr-2014-011548
M3 - Article
C2 - 25636625
AN - SCOPUS:84964211319
SN - 1757-790X
VL - 2015
JO - BMJ Case Reports
JF - BMJ Case Reports
M1 - 170
ER -