The Effects of Lateral 45° Head-Down Position and Carbon Dioxide Pneumoperitoneum on the Optic Nerve Sheath Diameter in Patients Undergoing Laparoscopic Transperitoneal Nephrectomies: A Prospective Observational Study

Ayşe Gülşah Atasever, Emine Aysu Salviz, Hayriye Ažentürk Çiftçi, Emre Sertaç Bingül, Nükhet Sivrikoz, Selcuk Erdem, Meltem Savran Karadeniz

Research output: Contribution to journalArticlepeer-review

Abstract

Background: The aim of this study is to assess the extent of the increased intracranial pressure resulting from lateral decubitus and 45° downward positioning using sonographic optic nerve sheath diameter (ONSD) in patients undergoing laparoscopic transperitoneal nephrectomy. In addition, we evaluated the effect of the carbon dioxide pneumoperitoneum (CO2PP) on ONSD. Materials and Methods: Twenty-four adults were enrolled in this prospective observational study. Longitudinal and transverse ONSDs were measured for each eye by ocular ultrasonography. The values were noted in supine position (T0), 20 minutes after induction of anesthesia (T1), after insufflation of the abdomen in lateral 45° head-down position (T2), at 30-minute intervals during surgery (T3-T4-T5), during lateral 45° head-down position after CO2 exsufflation (T6), before awakening while supine (T7), and at postoperative 24th hour (T8). Hemodynamic and respiratory parameters were investigated at the measurement time points. Results: Average ONSD values for the lower eye was T0 = 4.27 ± 0.4 mm, T1 = 4.56 ± 0.6 mm, T2 = 4.84 ± 0.6 mm, T3 = 4.91 ± 0.4 mm, T4 = 4.99 ± 0.5 mm, T5 = 4.97 ± 0.5 mm T6 = 4.96 ± 0.5 mm, T7 = 4.76 ± 0.4 mm, T8 = 4.36 ± 0.5 mm and for the upper eye was T0 = 4.24 ± 0.4 mm, T1 = 4.39 ± 0.5 mm, T2 = 4.54 ± 0.5 mm, T3 = 4.60 ± 0.4 mm, T4 = 4.66 ± 0.4 mm, T5 = 4.72 ± 0.7 mm, T6 = 4.68 ± 0.4 mm, T7 = 4.52 ± 0.4 mm, T8 = 4.30 ± 0.4 mm (P < .001). Conclusion: In our study, we observed a significant increase in ONSD within minutes after the patient was placed in a head-down position. We also observed that the difference increased more with CO2PP and was proportional to the length of the surgery. We found that it regressed to initial levels at the postoperative 24th hour. Clinicaltrials.gov: NCT05185908.

Original languageEnglish
Pages (from-to)171-176
Number of pages6
JournalJournal of Laparoendoscopic and Advanced Surgical Techniques
Volume33
Issue number2
DOIs
StatePublished - Feb 1 2023

Keywords

  • carbon dioxide pneumoperitoneum
  • laparoscopic transperitoneal nephrectomy
  • lateral 45° head-down position
  • ocular sonography
  • optic nerve sheath diameter

Fingerprint

Dive into the research topics of 'The Effects of Lateral 45° Head-Down Position and Carbon Dioxide Pneumoperitoneum on the Optic Nerve Sheath Diameter in Patients Undergoing Laparoscopic Transperitoneal Nephrectomies: A Prospective Observational Study'. Together they form a unique fingerprint.

Cite this