T1 - The current status and shortcomings of stereotactic radiosurgery
AU - Mehrens, Hunter
AU - Nguyen, Trang
AU - Edward, Sharbacha
AU - Hartzell, Shannon
AU - Glenn, Mallory
AU - Branco, Daniela
AU - Hernandez, Nadia
AU - Alvarez, Paola
AU - Molineu, Andrea
AU - Taylor, Paige
AU - Kry, Stephen
N1 - Publisher Copyright:
© 2022 The Author(s). Published by Oxford University Press, the Society for Neuro-Oncology and the European Association of Neuro-Oncology.
PY - 2022/1/1
Y1 - 2022/1/1
N2 - Background: Stereotactic radiosurgery (SRS) is a common treatment for intracranial lesions. This work explores the state of SRS treatment delivery to characterize current treatment accuracy based on treatment parameters. Methods: NCI clinical trials involving SRS rely on an end-to-end treatment delivery on a patient surrogate (credentialing phantom) from the Imaging and Radiation Oncology Core (IROC) to test their treatment accuracy. The results of 1072 SRS phantom irradiations between 2012 and 2020 were retrospectively analyzed. Univariate analysis and random forest models were used to associate irradiation conditions with phantom performance. The following categories were evaluated in terms of how they predicted outcomes: year of irradiation, TPS algorithm, machine model, energy, and delivered field size. Results: Overall, only 84.6% of irradiations have met the IROC/NCI acceptability criteria. Pass rate has remained constant over time, while dose calculation accuracy has slightly improved. Dose calculation algorithm (P <. 001), collimator (P =. 024), and field size (P <. 001) were statistically significant predictors of pass/fail. Specifically, pencil beam algorithms and cone collimators were more likely to be associated with failing phantom results. Random forest modeling identified the size of the field as the most important factor for passing or failing followed by algorithm. Conclusion: Constant throughout this retrospective study, approximately 15% of institutions fail to meet IROC/NCI standards for SRS treatment. In current clinical practice, this is particularly associated with smaller fields that yielded less accurate results. There is ongoing need to improve small field dosimetry, beam modeling, and QA to ensure high treatment quality, patient safety, and optimal clinical trials.
AB - Background: Stereotactic radiosurgery (SRS) is a common treatment for intracranial lesions. This work explores the state of SRS treatment delivery to characterize current treatment accuracy based on treatment parameters. Methods: NCI clinical trials involving SRS rely on an end-to-end treatment delivery on a patient surrogate (credentialing phantom) from the Imaging and Radiation Oncology Core (IROC) to test their treatment accuracy. The results of 1072 SRS phantom irradiations between 2012 and 2020 were retrospectively analyzed. Univariate analysis and random forest models were used to associate irradiation conditions with phantom performance. The following categories were evaluated in terms of how they predicted outcomes: year of irradiation, TPS algorithm, machine model, energy, and delivered field size. Results: Overall, only 84.6% of irradiations have met the IROC/NCI acceptability criteria. Pass rate has remained constant over time, while dose calculation accuracy has slightly improved. Dose calculation algorithm (P <. 001), collimator (P =. 024), and field size (P <. 001) were statistically significant predictors of pass/fail. Specifically, pencil beam algorithms and cone collimators were more likely to be associated with failing phantom results. Random forest modeling identified the size of the field as the most important factor for passing or failing followed by algorithm. Conclusion: Constant throughout this retrospective study, approximately 15% of institutions fail to meet IROC/NCI standards for SRS treatment. In current clinical practice, this is particularly associated with smaller fields that yielded less accurate results. There is ongoing need to improve small field dosimetry, beam modeling, and QA to ensure high treatment quality, patient safety, and optimal clinical trials.
KW - IROC
KW - phantoms
KW - QA
KW - random forest
KW - SRS
UR - http://www.scopus.com/inward/record.url?scp=85134909217&partnerID=8YFLogxK
U2 - 10.1093/noajnl/vdac058
DO - 10.1093/noajnl/vdac058
M3 - Article
AN - SCOPUS:85134909217
SN - 2632-2498
VL - 4
JO - Neuro-Oncology Advances
JF - Neuro-Oncology Advances
IS - 1
M1 - vdac058
ER -