TH‐C‐M100J‐08: Dosimetric Effects of a 4D Magnetic Localization System for LINAC Beam Gating On Prostate and Lung Radiation Therapy

P. Parikh, K. Lechleiter, K. Malinowski, B. Sargent, J. Peterson, J. Newell, J. Bradley, D. Low

    Research output: Contribution to journalArticlepeer-review

    3 Scopus citations

    Abstract

    Purpose: The Calypso® Medical 4D Localization System is capable of tracking continuous dynamic motion, and has been FDA cleared for use in the prostate. To date, automatic intervention for the measured motion is not a function of the system. We investigated use of the system to gate radiation therapy delivery on a motion phantom for both a lung and prostate fraction Materials and Methods: A Calypso gating prototype system with an optically isolated relay was connected to the BEAM_HOLD interface of a Varian Trilogy linac. A sample 3D lung plan and SMLC prostate plan were randomly selected from the active patient list. The Washington University 4D phantom was programmed to move a film box through 2 patient‐measured prostate and lung trajectories. Radiation therapy was delivered to the static phantom, to the phantom undergoing each motion trajectory without gating, and to the phantom undergoing motion trajectories while the Calypso System was gating the linac. A 4×4×4 mm gating window centered on isocenter was used for the prostate, while a linear gating window corresponding to exhalation (ie 2 mm<y<5 mm) was used for the lung. Results: Without gating beam delivery, prostate motion during treatment delivery caused approximately 10% underdosing and overdosing due to the superior/inferior and anterior/posterior prostate motion. The Calypso System triggering gated therapy delivery reduced these areas significantly, as seen in difference images using film dosimetry. Likewise, lung tumor motion caused a geometric mismatch between static and motion delivery. The Calypso System with prototype gating showed a decrease in this mismatch. Conclusions: A wireless electromagnetic implanted transponder system for linac gating was effective in reducing dosimetric errors caused by prostate and lung motion. More work is needed to define optimal gating windows to provide maximal clinical efficiency with minimal delivery error. This work was supported by Calypso Medical Technologies.

    Original languageEnglish
    Number of pages1
    JournalMedical physics
    Volume34
    Issue number6
    DOIs
    StatePublished - Jun 2007

    Fingerprint

    Dive into the research topics of 'TH‐C‐M100J‐08: Dosimetric Effects of a 4D Magnetic Localization System for LINAC Beam Gating On Prostate and Lung Radiation Therapy'. Together they form a unique fingerprint.

    Cite this