T1 - Technical note
T2 - Institutional solution of clinical cine MRI for tumor motion evaluation in radiotherapy
AU - Kim, Taeho
AU - Wu, Yu
AU - Ji, Zhen
AU - Gach, H. Michael
AU - Knutson, Nels
AU - Mackey, Stacie
AU - Schmidt, Matthew
N1 - Publisher Copyright:
© 2022 The Authors. Journal of Applied Clinical Medical Physics published by Wiley Periodicals, LLC on behalf of The American Association of Physicists in Medicine.
PY - 2022/7
Y1 - 2022/7
N2 - Purpose: Since 4D-MRI is inadequate to capture dynamic respiratory variations, real-time cinematographic (cine) MRI is actively used in MR-guided radiotherapy (MRgRT) for tumor motion evaluation, delineation, and tracking. However, most radiotherapy imaging platforms do not support the format of cine MRI from clinical MRI systems. This study developed an institutional solution of clinical cine MRI for tumor motion evaluation in radiotherapy applications. Methods: Cine MRI manipulation software (called Cine Viewer) was developed within a commercial Treatment Planning System (TPS). It consists of (1) single/orthogonal viewers, (2) display controllers, (3) measurement grids/markers, and (4) manual contouring tools. Results: The institutional solution of clinical cine MRI incorporated with radiotherapy application was assessed through case presentations (liver cancer). Cine Viewer loaded cine MRIs from 1.5T Philips Ingenia MRI, handling MRI DICOM format. The measurement grids and markers were used to quantify the displacement of anatomical structures in addition to the tumor. The contouring tool was utilized to localize the tumor and surrogates on the designated frame. The stacks of the contours were exhibited to present the ranges of tumor and surrogate motions. For example, the stacks of the tumor contours from case-1 were used to determine the ranges of tumor motions (∼8.17 mm on the x-direction [AP-direction] and ∼14 mm on the y-direction [SI-direction]). In addition, the patterns of the displacement of the contours over frames were analyzed and reported using in-house software. In the case-1 review, the tumor was displaced from +146.0 mm on the x-direction and +125.0 mm on the y-direction from the ROI of the abdominal surface. Conclusion: We demonstrated the institutional solution of clinical cine MRI in radiotherapy. The proposed tools can streamline the utilization of cine MRI for tumor motion evaluation using Eclipse for treatment planning.
AB - Purpose: Since 4D-MRI is inadequate to capture dynamic respiratory variations, real-time cinematographic (cine) MRI is actively used in MR-guided radiotherapy (MRgRT) for tumor motion evaluation, delineation, and tracking. However, most radiotherapy imaging platforms do not support the format of cine MRI from clinical MRI systems. This study developed an institutional solution of clinical cine MRI for tumor motion evaluation in radiotherapy applications. Methods: Cine MRI manipulation software (called Cine Viewer) was developed within a commercial Treatment Planning System (TPS). It consists of (1) single/orthogonal viewers, (2) display controllers, (3) measurement grids/markers, and (4) manual contouring tools. Results: The institutional solution of clinical cine MRI incorporated with radiotherapy application was assessed through case presentations (liver cancer). Cine Viewer loaded cine MRIs from 1.5T Philips Ingenia MRI, handling MRI DICOM format. The measurement grids and markers were used to quantify the displacement of anatomical structures in addition to the tumor. The contouring tool was utilized to localize the tumor and surrogates on the designated frame. The stacks of the contours were exhibited to present the ranges of tumor and surrogate motions. For example, the stacks of the tumor contours from case-1 were used to determine the ranges of tumor motions (∼8.17 mm on the x-direction [AP-direction] and ∼14 mm on the y-direction [SI-direction]). In addition, the patterns of the displacement of the contours over frames were analyzed and reported using in-house software. In the case-1 review, the tumor was displaced from +146.0 mm on the x-direction and +125.0 mm on the y-direction from the ROI of the abdominal surface. Conclusion: We demonstrated the institutional solution of clinical cine MRI in radiotherapy. The proposed tools can streamline the utilization of cine MRI for tumor motion evaluation using Eclipse for treatment planning.
KW - Eclipse
KW - cine MRI
KW - tumor motion correlation
KW - tumor motion evaluation
UR - http://www.scopus.com/inward/record.url?scp=85130889157&partnerID=8YFLogxK
U2 - 10.1002/acm2.13650
DO - 10.1002/acm2.13650
M3 - Article
C2 - 35615991
AN - SCOPUS:85130889157
SN - 1526-9914
VL - 23
JO - Journal of applied clinical medical physics
JF - Journal of applied clinical medical physics
IS - 7
M1 - e13650
ER -