TY - JOUR
T1 - Tc-99m sulfur colloid scintigraphy for detecting perigraft flow following endovascular aortic aneurysm repair
T2 - A feasibility study
AU - Hovsepian, David M.
AU - Siegel, Barry A.
AU - Kimbiris, George
AU - Sicard, Gregorio A.
AU - Allen, Brent T.
AU - Picus, Daniel
PY - 1999/11
Y1 - 1999/11
N2 - Purpose: To determine if scintigraphy with Tc-99m sulfur colloid can be used to detect perigraft flow after stent-graft repair of abdominal aortic aneurysm (AAA). Methods: Twenty-three men and two women aged 56-84 years (mean 71 years) underwent endoluminal AAA repair as part of the EVT Phase II trial [EVT = Endovascular Technologies (Menlo Park, CA, USA)]. Aneurysm size averaged 5.4 cm (range 3-8 cm). Sixteen bifurcated, seven tube, and two aorto-uniiliac grafts were placed. Two days after stent-graft placement, patients underwent both contrast-enhanced computed tomography (CT), including delayed views, and Tc-99m sulfur colloid scintigraphy. Results: Perigraft flow was found in only one patient at completion of angiography. Four additional patients had perigraft flow, discovered during their postoperative follow-up CT. Four patients had leaks at an attachment site and one had retrograde branch flow. Tc-99m sulfur colloid scintigraphy failed to diagnose any of the five leaks prospectively. In two of these patients, however, some abnormal paraaortic activity was noted in retrospect. Conclusion: Tc-99m sulfur colloid scintigraphy was unable to demonstrate endoleak with either rapid flow (attachment site leak) or slow filling (branch flow).
AB - Purpose: To determine if scintigraphy with Tc-99m sulfur colloid can be used to detect perigraft flow after stent-graft repair of abdominal aortic aneurysm (AAA). Methods: Twenty-three men and two women aged 56-84 years (mean 71 years) underwent endoluminal AAA repair as part of the EVT Phase II trial [EVT = Endovascular Technologies (Menlo Park, CA, USA)]. Aneurysm size averaged 5.4 cm (range 3-8 cm). Sixteen bifurcated, seven tube, and two aorto-uniiliac grafts were placed. Two days after stent-graft placement, patients underwent both contrast-enhanced computed tomography (CT), including delayed views, and Tc-99m sulfur colloid scintigraphy. Results: Perigraft flow was found in only one patient at completion of angiography. Four additional patients had perigraft flow, discovered during their postoperative follow-up CT. Four patients had leaks at an attachment site and one had retrograde branch flow. Tc-99m sulfur colloid scintigraphy failed to diagnose any of the five leaks prospectively. In two of these patients, however, some abnormal paraaortic activity was noted in retrospect. Conclusion: Tc-99m sulfur colloid scintigraphy was unable to demonstrate endoleak with either rapid flow (attachment site leak) or slow filling (branch flow).
KW - Aneurysm, aortic
KW - Aorta, grafts and prostheses
KW - Radionuclide imaging, experimental
UR - http://www.scopus.com/inward/record.url?scp=0032797283&partnerID=8YFLogxK
U2 - 10.1007/s002709900430
DO - 10.1007/s002709900430
M3 - Article
C2 - 10556401
AN - SCOPUS:0032797283
SN - 0174-1551
VL - 22
SP - 447
EP - 451
JO - Cardiovascular and Interventional Radiology
JF - Cardiovascular and Interventional Radiology
IS - 6
ER -