TY - JOUR
T1 - Targeting tumor hypoxia
T2 - A third generation 2-nitroimidazole-indocyanine dye-conjugate with improved fluorescent yield
AU - Zhou, Feifei
AU - Zanganeh, Saeid
AU - Mohammad, Innus
AU - Dietz, Christopher
AU - Abuteen, Akram
AU - Smith, Michael B.
AU - Zhu, Quing
N1 - Publisher Copyright:
© The Royal Society of Chemistry.
PY - 2015/9/17
Y1 - 2015/9/17
N2 - Tumor hypoxia is associated with the rapid proliferation and growth of malignant tumors, and the ability to detect tumor hypoxia is important for predicting tumor response to anti-cancer treatments. We have developed a class of dye-conjugates that are related to indocyanine green (ICG, 1) to target tumor hypoxia, based on in vivo infrared fluorescence imaging using nitroimidazole moieties linked to indocyanine fluorescent dyes. We previously reported that linking 2-nitroimidazole to an indocyanine dicarboxylic acid dye derivative (2) using an ethanolamine linker (ethanolamine-2-nitroimidazole-ICG, 3), led to a dye-conjugate that gave promising results for targeting cancer hypoxia in vivo. Structural modification of the dye conjugate replaced the ethanolamine unit with a piperazineacetyl unit and led a second generation dye conjugate, piperzine-2-nitroimidazole-ICG (4). This second generation dye-conjugate showed improved targeting of tumor hypoxia when compared with 3. Based on the hypothesis that molecules with more planar and rigid structures have a higher fluorescence yield, as they could release less absorbed energy through molecular vibration or collision, we have developed a new 2-nitroimidazole ICG conjugate, 12, with two carbon atoms less in the polyene linker. Dye-conjugate 12 was prepared from our new dye (8), and coupled to 2-nitroimidazole using a piperazine linker to produce this third-generation dye-conjugate. Spectral measurements showed that the absorption/emission wavelengths of 657/670 were shifted ∼100 nm from the second-generation hypoxia dye of 755/780 nm. Its fluorescence quantum yield was measured to be 0.467, which is about 5 times higher than that of 4 (0.083). In vivo experiments were conducted with balb/c mice and 12 showed more than twice the average in vivo fluorescence intensity in the tumor beyond two hours post retro-orbital injection as compared with 4. These initial results suggest that 12 may significantly improve in vivo tumor hypoxia targeting.
AB - Tumor hypoxia is associated with the rapid proliferation and growth of malignant tumors, and the ability to detect tumor hypoxia is important for predicting tumor response to anti-cancer treatments. We have developed a class of dye-conjugates that are related to indocyanine green (ICG, 1) to target tumor hypoxia, based on in vivo infrared fluorescence imaging using nitroimidazole moieties linked to indocyanine fluorescent dyes. We previously reported that linking 2-nitroimidazole to an indocyanine dicarboxylic acid dye derivative (2) using an ethanolamine linker (ethanolamine-2-nitroimidazole-ICG, 3), led to a dye-conjugate that gave promising results for targeting cancer hypoxia in vivo. Structural modification of the dye conjugate replaced the ethanolamine unit with a piperazineacetyl unit and led a second generation dye conjugate, piperzine-2-nitroimidazole-ICG (4). This second generation dye-conjugate showed improved targeting of tumor hypoxia when compared with 3. Based on the hypothesis that molecules with more planar and rigid structures have a higher fluorescence yield, as they could release less absorbed energy through molecular vibration or collision, we have developed a new 2-nitroimidazole ICG conjugate, 12, with two carbon atoms less in the polyene linker. Dye-conjugate 12 was prepared from our new dye (8), and coupled to 2-nitroimidazole using a piperazine linker to produce this third-generation dye-conjugate. Spectral measurements showed that the absorption/emission wavelengths of 657/670 were shifted ∼100 nm from the second-generation hypoxia dye of 755/780 nm. Its fluorescence quantum yield was measured to be 0.467, which is about 5 times higher than that of 4 (0.083). In vivo experiments were conducted with balb/c mice and 12 showed more than twice the average in vivo fluorescence intensity in the tumor beyond two hours post retro-orbital injection as compared with 4. These initial results suggest that 12 may significantly improve in vivo tumor hypoxia targeting.
UR - https://www.scopus.com/pages/publications/84947967303
U2 - 10.1039/c5ob01460c
DO - 10.1039/c5ob01460c
M3 - Article
C2 - 26403518
AN - SCOPUS:84947967303
SN - 1477-0520
VL - 13
SP - 11220
EP - 11227
JO - Organic and Biomolecular Chemistry
JF - Organic and Biomolecular Chemistry
IS - 46
ER -