T1 - Systemic-to-pulmonary collateral flow, as measured by cardiac magnetic resonance imaging, is associated with acute post-fontan clinical outcomes
AU - Glatz, Andrew C.
AU - Rome, Jonathan J.
AU - Small, Adam J.
AU - Gillespie, Matthew J.
AU - Dori, Yoav
AU - Harris, Matthew A.
AU - Keller, Marc S.
AU - Fogel, Mark A.
AU - Whitehead, Kevin K.
PY - 2012/3
Y1 - 2012/3
N2 - Background-Systemic-pulmonary collateral (SPC) flow occurs commonly in single ventricle patients after superior cavo-pulmonary connection, with unclear clinical significance. We sought to evaluate the association between SPC flow and acute post-Fontan clinical outcomes using a novel method of quantifying SPC flow by cardiac magnetic resonance (CMR) imaging. Methods and Results-All patients who had SPC flow quantified by CMR imaging before Fontan were retrospectively reviewed to assess for acute clinical outcomes after Fontan completion. Forty-four subjects were included who had Fontan completion between May 2008 and September 2010. SPC flow prior to Fontan measured 1.5±0.9 L/min/m2, accounting for 31±11% of total aortic flow and 44±15% of total pulmonary venous flow. There was a significant linear association between natural log-transformed duration of hospitalization and SPC flow as a proportion of total aortic (rho=0.31, P=0.04) and total pulmonary venous flow (rho=0.29, P=0.05). After adjustment for Fontan type and presence of a fenestration, absolute SPC flow was significantly associated with hospital duration ≥7 days (odds ratio [OR]=9.2, P=0.02) and chest tube duration ≥10 days (OR=22.7, P=0.009). Similar associations exist for SPC flow as a percentage of total aortic (OR=1.09, P=0.048 for hospitalization ≥7 days; OR=1.24, P=0.007 for chest tube duration ≥10 days) and total pulmonary venous flow (OR=1.07, P=0.048 for hospitalization ≥7 days; OR=1.18, P=0.006 for chest tube duration ≥10 days). Conclusions-Increasing SPC flow before Fontan, as measured by CMR imaging, is associated with increased duration of hospitalization and chest tube following Fontan completion.
AB - Background-Systemic-pulmonary collateral (SPC) flow occurs commonly in single ventricle patients after superior cavo-pulmonary connection, with unclear clinical significance. We sought to evaluate the association between SPC flow and acute post-Fontan clinical outcomes using a novel method of quantifying SPC flow by cardiac magnetic resonance (CMR) imaging. Methods and Results-All patients who had SPC flow quantified by CMR imaging before Fontan were retrospectively reviewed to assess for acute clinical outcomes after Fontan completion. Forty-four subjects were included who had Fontan completion between May 2008 and September 2010. SPC flow prior to Fontan measured 1.5±0.9 L/min/m2, accounting for 31±11% of total aortic flow and 44±15% of total pulmonary venous flow. There was a significant linear association between natural log-transformed duration of hospitalization and SPC flow as a proportion of total aortic (rho=0.31, P=0.04) and total pulmonary venous flow (rho=0.29, P=0.05). After adjustment for Fontan type and presence of a fenestration, absolute SPC flow was significantly associated with hospital duration ≥7 days (odds ratio [OR]=9.2, P=0.02) and chest tube duration ≥10 days (OR=22.7, P=0.009). Similar associations exist for SPC flow as a percentage of total aortic (OR=1.09, P=0.048 for hospitalization ≥7 days; OR=1.24, P=0.007 for chest tube duration ≥10 days) and total pulmonary venous flow (OR=1.07, P=0.048 for hospitalization ≥7 days; OR=1.18, P=0.006 for chest tube duration ≥10 days). Conclusions-Increasing SPC flow before Fontan, as measured by CMR imaging, is associated with increased duration of hospitalization and chest tube following Fontan completion.
KW - Aortopulmonary collaterals
KW - Cardiac MRI
KW - Fontan procedure
KW - Outcomes
KW - Single ventricle
UR - http://www.scopus.com/inward/record.url?scp=84860786498&partnerID=8YFLogxK
U2 - 10.1161/CIRCIMAGING.111.966986
DO - 10.1161/CIRCIMAGING.111.966986
M3 - Review article
C2 - 22228054
AN - SCOPUS:84860786498
SN - 1941-9651
VL - 5
SP - 218
EP - 225
JO - Circulation: Cardiovascular Imaging
JF - Circulation: Cardiovascular Imaging
IS - 2
ER -