SU‐GG‐T‐572: Are Constant Dose Rate VMAT Plans Clinically Acceptable? — A Site‐By‐Site Plan Comparison Study

G. Palaniswaamy, K. Moore, D. Rangaraj, L. Santanam, D. Low

Research output: Contribution to journalArticlepeer-review

Abstract

Purpose: To evaluate the adequacy of constant dose rate (CDR) VMAT plans for clinical use of commonly treated sites. The clinical acceptability of CDR VMAT plans was evaluated based on plan quality comparisons against clinically used IMRT plans. Methods: Several patient treatments planned using IMRT were considered for the study and replanned using Pinnacle 9.0 (SmartArc) treatment planning system. Several clinical sites were considered for this study — prostate and prostate bed (4 patients), pelvis (1), breast (1) and head and neck (H&N) (2). The quality of CDR plans normalized to PTV mean dose was compared against static field IMRT plans based on dose conformality, planning target volume (PTV) coverage and dose volume histograms (DVHs) of organs at risk (OAR). Results: Plan qualities of prostate, prostate bed and pelvis plans were evaluated based on rectum and bladder DVHs, PTV coverage and dose conformality. Prostate and prostate bed: CDR plan was found to be clinically acceptable with better OAR sparing and delivery time. Pelvis: CDR plan was lacking coverage and conformality and didn't have a significant advantage over the IMRT plan. Breast: Plan quality was evaluated based on PTV coverage, isodose conformality and DVHs generated for OARs — lungs, heart and cord. The CDR plan was clinically unacceptable, primarily due to low doses (<10Gy) covering a large volume of the lungs. H&N plans were evaluated based on PTV coverage, dose conformality and dose to parotids, cord and submandibular glands. The CDR plans were clinically unacceptable and didn't show significant advantage over IMRT plans beyond the reduced treatment time. Conclusion: The CDR plans for prostate and prostate bed were clinically acceptable and found to be equivalent, if not superior to IMRT plans. For the other sites investigated ‐ pelvis, breast, and H&N, static field IMRT plans proved to be superior to CDR plans.

Original languageEnglish
Pages (from-to)3319
Number of pages1
JournalMedical physics
Volume37
Issue number6
DOIs
StatePublished - Jun 2010

Fingerprint

Dive into the research topics of 'SU‐GG‐T‐572: Are Constant Dose Rate VMAT Plans Clinically Acceptable? — A Site‐By‐Site Plan Comparison Study'. Together they form a unique fingerprint.

Cite this