SU‐GG‐J‐37: Assessing Image Guided Radiation Therapy Targeting Accuracy: Coincidence Of Imaging System Isocenter With Treatment Machine Mechanical And Radiation Isocenters

H. Saleh, D. Pokhrel, J. Williamson

Research output: Contribution to journalArticlepeer-review

Abstract

Purpose: The purpose of this study is to introduce a method for quantifying the accuracy of linac and imaging system isocenters and demonstrate its use by measuring the targeting of two kilovoltage (kV) imaging systems, and one gantry mounted megavoltage Electronic Portal Imaging Device (EPID). One is the kV imaging system (OBI) integrated with the linear accelerator which supports radiographic and cone beam CT imaging. The other system is the BrainLab Exac Trac stand alone fixed to the treatment room ceiling and floor. Method and Materials: A cylindrical Lucite phantom was designed and fabricated to perform this study. The cylindrical phantom is 20 cm in diameter and 20 cm long. The phantom contains 13 radio‐opaque fiducial markers. A 5 mm spherical marker is positioned at the center of the cylinder. The phantom was imaged and the CT data sets were imported to two planning systems. Treatment beams were placed and both 3D data sets and isocenter information were transferred to the Linac delivery and imaging workstations. For each imaging system, phantom was initially positioned according to machine cross‐hair. Then images were acquired and measured shifts were applied to precisely position the phantom. Then, Winston‐Lutz test was performed for different gantry and collimator configuration. The radiation beam was collimated by a tray‐mounted 30 mm diameter circular collimator. Results: The radius of spherical volume in which all isocenter intersect or lie was measured. For EPID, OBI, CBCT, and Exac Trac, the radius is: 0.54 mm, 1.4 mm, 1.7 mm and 1.46 mm respectively. From the Winston‐Lutz analysis, the average isocenter deviation from all angles is 1.18 ± 0.28 mm. Conclusion: The error in mechanical, radiation and imaging isocenter is about one millimeter. Regardless what imaging system is used for patient setup, it is important to incorporate this systematic error in any planning margins.

Original languageEnglish
Pages (from-to)2687
Number of pages1
JournalMedical physics
Volume35
Issue number6
DOIs
StatePublished - Jun 2008

Fingerprint

Dive into the research topics of 'SU‐GG‐J‐37: Assessing Image Guided Radiation Therapy Targeting Accuracy: Coincidence Of Imaging System Isocenter With Treatment Machine Mechanical And Radiation Isocenters'. Together they form a unique fingerprint.

Cite this