T1 - SU‐FF‐J‐67
T2 - Fiducial‐Based Translation Alignment Accuracy of An AC Electromagnetic Tracking System and On‐Board Kilovoltage Imaging Localization System
AU - Santanam, L.
AU - Parikh, P.
AU - Malinowski, K.
AU - Esthappan, J.
AU - Hubenschmidt, J.
AU - Goddu, S.
AU - Dimmer, S.
AU - Mutic, S.
AU - Low, D.
PY - 2006/6
Y1 - 2006/6
N2 - Purpose: On‐board kilovoltage imaging is being used for accurate fiducial‐based alignment of tumors. However, these systems deliver additional dose to the patient and do not allow interactive repositioning with the therapist in the room. The purpose of this study is to measure and compare static localization accuracy of a commercial on‐board kilovoltage imaging system and a novel AC electromagnetic tracking system. Materials and Methods: A kilovoltage imaging system (Trilogy™ System, Varian, Palo Alto, CA) and an electromagnetic tracking system (Calypso® 4D Localization System, Calypso Medical, Seattle, WA) which provides a continuous measurement of the implanted transponder positions, were compared for localization accuracy. A phantom containing three radiofrequency transponders was moved, using an in‐house developed 4D phantom (with a 0.4 mm position accuracy), in steps from 0.4 cm to 5 cm in the lateral, longitudinal, and vertical directions. The transponder positions were measured using the commercial matching software using antero‐posterior and lateral images and comparing against DRRs. These results were compared against the Calypso System measurements. Results: The localization accuracy, defined as the average difference of the measured positions (by the localization systems) to the actual positions (as determined by 4D‐ phantom positioning system) was found to be 0.0 ± 0.00 cm, 0.1 ± 0.1 cm and 0.1 ± 0.0 cm in three directions for KV system and 0.0 ± 0.0 cm for the Calypso system. Results showed that both systems provided excellent positioning accuracy.
AB - Purpose: On‐board kilovoltage imaging is being used for accurate fiducial‐based alignment of tumors. However, these systems deliver additional dose to the patient and do not allow interactive repositioning with the therapist in the room. The purpose of this study is to measure and compare static localization accuracy of a commercial on‐board kilovoltage imaging system and a novel AC electromagnetic tracking system. Materials and Methods: A kilovoltage imaging system (Trilogy™ System, Varian, Palo Alto, CA) and an electromagnetic tracking system (Calypso® 4D Localization System, Calypso Medical, Seattle, WA) which provides a continuous measurement of the implanted transponder positions, were compared for localization accuracy. A phantom containing three radiofrequency transponders was moved, using an in‐house developed 4D phantom (with a 0.4 mm position accuracy), in steps from 0.4 cm to 5 cm in the lateral, longitudinal, and vertical directions. The transponder positions were measured using the commercial matching software using antero‐posterior and lateral images and comparing against DRRs. These results were compared against the Calypso System measurements. Results: The localization accuracy, defined as the average difference of the measured positions (by the localization systems) to the actual positions (as determined by 4D‐ phantom positioning system) was found to be 0.0 ± 0.00 cm, 0.1 ± 0.1 cm and 0.1 ± 0.0 cm in three directions for KV system and 0.0 ± 0.0 cm for the Calypso system. Results showed that both systems provided excellent positioning accuracy.
UR - http://www.scopus.com/inward/record.url?scp=85024793896&partnerID=8YFLogxK
U2 - 10.1118/1.2240845
DO - 10.1118/1.2240845
M3 - Article
AN - SCOPUS:85024793896
SN - 0094-2405
VL - 33
SP - 2035
EP - 2036
JO - Medical physics
JF - Medical physics
IS - 6
ER -