T1 - Sub-nanowatt ultrasonic bio-telemetry using B-scan imaging
AU - Kondapalli, Sri Harsha
AU - Chakrabartty, Shantanu
N1 - Publisher Copyright:
© 2020 IEEE.
PY - 2021
Y1 - 2021
N2 - Goal: The objective of this paper is to investigate if the use of a B-scan ultrasound imaging system can reduce the energy requirements, and hence the power-dissipation requirements to support wireless bio-telemetry at an implantable device. Methods: B-scan imaging data were acquired using a commercial 256-element linear ultrasound transducer array which was driven by a commercial echoscope. As a transmission medium, we used a water-bath and the operation of the implantable device was emulated using a commercial-off-the-shelf micro-controller board. The telemetry parameters (e.g. transmission rate and transmission power) were wirelessly controlled using a two-way radio-frequency transceiver. B-scan imaging data were post-processed using a maximum-threshold decoder and the quality of the ultrasonic telemetry link was quantified in terms of its bit-error-rate (BER). Results: Measured results show that a reliable B-scan communication link with an implantable device can be achieved at transmission power levels of 100 pW and for implantation depths greater than 10 cm. Conclusions: In this paper we demonstrated that a combination of B-scan imaging and a simple decoding algorithm can significantly reduce the energy-budget requirements for reliable ultrasonic telemetry.
AB - Goal: The objective of this paper is to investigate if the use of a B-scan ultrasound imaging system can reduce the energy requirements, and hence the power-dissipation requirements to support wireless bio-telemetry at an implantable device. Methods: B-scan imaging data were acquired using a commercial 256-element linear ultrasound transducer array which was driven by a commercial echoscope. As a transmission medium, we used a water-bath and the operation of the implantable device was emulated using a commercial-off-the-shelf micro-controller board. The telemetry parameters (e.g. transmission rate and transmission power) were wirelessly controlled using a two-way radio-frequency transceiver. B-scan imaging data were post-processed using a maximum-threshold decoder and the quality of the ultrasonic telemetry link was quantified in terms of its bit-error-rate (BER). Results: Measured results show that a reliable B-scan communication link with an implantable device can be achieved at transmission power levels of 100 pW and for implantation depths greater than 10 cm. Conclusions: In this paper we demonstrated that a combination of B-scan imaging and a simple decoding algorithm can significantly reduce the energy-budget requirements for reliable ultrasonic telemetry.
KW - B-Scan imaging
KW - echoscope
KW - low-power communication
KW - ultrasound telemetry
UR - http://www.scopus.com/inward/record.url?scp=85121060830&partnerID=8YFLogxK
U2 - 10.1109/OJEMB.2021.3053174
DO - 10.1109/OJEMB.2021.3053174
M3 - Article
AN - SCOPUS:85121060830
SN - 2644-1276
VL - 2
SP - 17
EP - 25
JO - IEEE Open Journal of Engineering in Medicine and Biology
JF - IEEE Open Journal of Engineering in Medicine and Biology
M1 - 9329112
ER -