Sensing lead-related complications in patients with transvenous implantable cardioverter-defibrillators

  • Jennifer S. Lawton
  • , Kenneth A. Ellenbogen
  • , Mark A. Wood
  • , Bruce S. Stambler
  • , John M. Herre
  • , Sunil Nath
  • , Robert C. Bernstein
  • , John P. DiMarco
  • , David E. Haines
  • , Szabolcs Szentpetery
  • , Lenox D. Baker
  • , Ralph J. Damiano

Research output: Contribution to journalArticlepeer-review

Abstract

The widespread use of the redesigned Endotak™ lead (CPI, St. Paul, Minnesota), which combines transvenous pacing, sensing, and defibrillation on a single transvenous lead in patients receiving transvenous implantable cardioverter-defibrillators (ICDs), has reduced morbidity and shortened length of hospital stay after ICD implantation. We describe the incidence and management of Endotak sensing lead-related failures in a series of 348 consecutive patients from 4 institutions who underwent implantation between 1990 and 1995. We retrospectively reviewed the databases for patients receiving an ICD with an Endotak lead for the incidence of lead-related sensing abnormalities. Ten patients (2.8%) with lead-related sensing abnormalities were detected at a mean of 15 ± 11 months after ICD implantation. Sensing abnormalities were detected in 6 patients after they received inappropriate shocks. Noise or oversensing was noted in 7 patients from interrogation of the devices' data logs. Eight patients had a new transvenous sensing lead placed, 1 patient had a new Endotak lead placed, and 1 had a chronic pacemaker sensing lead converted to function as a sensing lead. No further sensing problems were noted in 8 of 10 patients during a mean follow-up of 14 ± 8 months. The site of the sensing lead failure was localized to the subrectus pocket in 5 patients and to the clavicle-first rib area in 3 patients; it was undetermined and presumed to be in the clavicle-first rib area in the other 2 patients. One patient had late failure of the defibrillation lead. We conclude that Endotak sensing lead failure does not require insertion of a new Endotak lead, but can be managed with close follow-up and insertion of a new transvenous sensing lead. Endotak lead fractures are frequently localized to the ICD pocket.

Original languageEnglish
Pages (from-to)647-651
Number of pages5
JournalAmerican Journal of Cardiology
Volume78
Issue number6
DOIs
StatePublished - 1996

Fingerprint

Dive into the research topics of 'Sensing lead-related complications in patients with transvenous implantable cardioverter-defibrillators'. Together they form a unique fingerprint.

Cite this