Rotational Fluoroscopy Assists in Detection of Intra-Articular Screw Penetration During Volar Plating of the Distal Radius

Matthew L. Tweet, Ryan P. Calfee, Peter J. Stern

Research output: Contribution to journalArticlepeer-review

16 Scopus citations

Abstract

Purpose: Intra-articular screw penetration is one complication of volar plate fixation of distal radius fractures. This study was designed to determine the most commonly used imaging techniques and views during volar plating of distal radius fractures and to evaluate surgeons' ability to detect intra-articular screw placement on static fluoroscopic images and rotational fluoroscopy. Methods: Active members of the American Society for Surgery of the Hand were polled regarding preferred imaging techniques (fluoroscopic vs cassette radiographs) and views (rotational fluoroscopy or static orthogonal/anatomic tilt/semipronated imaging) during volar plating of distal radius fractures. After the survey, volar locking plates were applied to 30 cadaveric distal radiuses. We intentionally penetrated a single screw into the radiocarpal joint in half of the specimens (15 arms) and intentionally did not penetrate the radiocarpal joint in the other half. Imaging (standard posteroanterior [PA] and lateral views, 11° tilt PA and 22° tilt lateral views, and two 360° fluoroscopy movies) was performed using a custom jig. Five surgeons blinded to results reviewed randomized image sets evaluating for intra-articular screw placement. Receiver operating characteristic curves were constructed to compare the reliability of each fluoroscopic projection or movie. Results: Among 696 survey respondents, 606 exclusively used fluoroscopic imaging (without cassette radiographs) and over 450 preferred either tilt images or rotational fluoroscopy to detect intra-articular screw penetration. In our cadaveric model, rotational fluoroscopy provided the highest sensitivity (93%) and specificity (96%) for the detection of intra-articular screw penetration. Rotational fluoroscopy was significantly more reliable (p<.01) than most images (standard lateral, 11° PA, 22° lateral, paired PA/lateral) and trended strongly toward better reliability for all remaining images (standard PA [p=.07], paired 11° PA/22° lateral [p=.08], and 22° tilt fluoroscopy movie [p=.11]). Conclusions: Rotational fluoroscopy improves the surgeon's ability to detect intra-articular screw penetration during volar plating of the distal radius. No combination of imaging allowed detection of all intra-articular screws. A high level of suspicion for intra-articular screw penetration should be maintained during volar plating of distal radial fractures.

Original languageEnglish
Pages (from-to)619-627
Number of pages9
JournalJournal of Hand Surgery
Volume35
Issue number4
DOIs
StatePublished - Apr 2010

Keywords

  • Complication
  • distal radius
  • fluoroscopy
  • fracture
  • volar plate

Fingerprint

Dive into the research topics of 'Rotational Fluoroscopy Assists in Detection of Intra-Articular Screw Penetration During Volar Plating of the Distal Radius'. Together they form a unique fingerprint.

Cite this