TY - JOUR
T1 - Robotic Assistance for Posterior Approach Total Hip Arthroplasty Is Associated With Lower Risk of Revision for Dislocation When Compared to Manual Techniques
AU - Bendich, Ilya
AU - Vigdorchik, Jonathan M.
AU - Sharma, Abhi K.
AU - Mayman, David J.
AU - Sculco, Peter K.
AU - Anderson, Chris
AU - Della Valle, Alejandro Gonzalez
AU - Su, Edwin P.
AU - Jerabek, Seth A.
N1 - Funding Information:
We are grateful to Yu-Fen Chiu, MA for her assistance in study design and analysis and to the members of the Adult Reconstruction and Joint Replacement Service of (Hospital for Special Surgery) who contributed patients to this study. The study was possible due to the generous donation of William and Carol Browne.
Publisher Copyright:
© 2022 Elsevier Inc.
PY - 2022/6
Y1 - 2022/6
N2 - Background: Robotic-assistance total hip arthroplasty (RA-THA) and computer navigation THA (CN-THA) have been shown to improve accuracy of component positioning compared to manual techniques; however, controversy exists regarding clinical benefit. Moreover, these technologies may expose patients to risks. The purpose of this study is to compare rates of intraoperative fracture and complications requiring reoperation within 1 year for posterior approach RA-THA, CN-THA, and THA with no technology (Manual-THA). Methods: In total, 13,802 primary, unilateral, elective, posterior approach THAs (1770 RA-THAs, 3155 CN-THAs, and 8877 Manual-THAs) were performed at a single institution between 2016 and 2020. Intraoperative fractures and reoperations within 1 year of the index procedure were identified. Cohorts were balanced using inverse probability of treatment weight based on age, gender, body mass index, femoral cementation, history of spine fusion, and Charlson Comorbidity Index. Logistic regression was performed to create odds ratios for complications. Additional regression analysis for dislocation was performed, adjusting for dual mobility and femoral head size. Results: There were no differences in intraoperative fracture and postoperative complication rates between the groups (P = .521). RA-THA had a 0.3 odds ratio (95% confidence interval 0.1-0.9, P = .046) compared to Manual-THA for reoperation due to dislocation. CN-THA had an odds ratio of 3.0 for reoperation due to dislocation (95% confidence interval 0.8-11.3, P = .114) compared to RA-THA. The remaining complication odds ratios, including those for infection, loosening, dehiscence, and “other” were similar between the groups. Conclusion: RA-THA is associated with lower risk of revision for dislocation within 1 year of index surgery, when compared to Manual-THA performed through the posterior approach.
AB - Background: Robotic-assistance total hip arthroplasty (RA-THA) and computer navigation THA (CN-THA) have been shown to improve accuracy of component positioning compared to manual techniques; however, controversy exists regarding clinical benefit. Moreover, these technologies may expose patients to risks. The purpose of this study is to compare rates of intraoperative fracture and complications requiring reoperation within 1 year for posterior approach RA-THA, CN-THA, and THA with no technology (Manual-THA). Methods: In total, 13,802 primary, unilateral, elective, posterior approach THAs (1770 RA-THAs, 3155 CN-THAs, and 8877 Manual-THAs) were performed at a single institution between 2016 and 2020. Intraoperative fractures and reoperations within 1 year of the index procedure were identified. Cohorts were balanced using inverse probability of treatment weight based on age, gender, body mass index, femoral cementation, history of spine fusion, and Charlson Comorbidity Index. Logistic regression was performed to create odds ratios for complications. Additional regression analysis for dislocation was performed, adjusting for dual mobility and femoral head size. Results: There were no differences in intraoperative fracture and postoperative complication rates between the groups (P = .521). RA-THA had a 0.3 odds ratio (95% confidence interval 0.1-0.9, P = .046) compared to Manual-THA for reoperation due to dislocation. CN-THA had an odds ratio of 3.0 for reoperation due to dislocation (95% confidence interval 0.8-11.3, P = .114) compared to RA-THA. The remaining complication odds ratios, including those for infection, loosening, dehiscence, and “other” were similar between the groups. Conclusion: RA-THA is associated with lower risk of revision for dislocation within 1 year of index surgery, when compared to Manual-THA performed through the posterior approach.
KW - Robotics
KW - complications
KW - navigation
KW - technology-assisted arthroplasty
KW - total hip arthroplasty
UR - http://www.scopus.com/inward/record.url?scp=85125750074&partnerID=8YFLogxK
U2 - 10.1016/j.arth.2022.01.085
DO - 10.1016/j.arth.2022.01.085
M3 - Article
C2 - 35124193
AN - SCOPUS:85125750074
SN - 0883-5403
VL - 37
SP - 1124
EP - 1129
JO - Journal of Arthroplasty
JF - Journal of Arthroplasty
IS - 6
ER -