TY - JOUR
T1 - Risk factors for acute adverse events during ultrasound-guided central venous cannulation in the emergency department
AU - Theodoro, Daniel
AU - Krauss, Missy
AU - Kollef, Marin
AU - Evanoff, Bradley
PY - 2010/10
Y1 - 2010/10
N2 - Background: Ultrasound (US) greatly facilitates cannulation of the internal jugular vein. Despite the ability to visualize the needle and anatomy, adverse events still occur. The authors hypothesized that the technique has limitations among certain patients and clinical scenarios. Objectives: The purpose of this study was to identify characteristics of adverse events surrounding US-guided central venous cannulation (CVC). Methods: The authors assembled a prospective observational cohort of emergency department (ED) patients undergoing consecutive internal jugular CVC with US. The primary outcome of interest was a composite of acute mechanical adverse events including hematoma, arterial cannulation, pneumothorax, and unsuccessful placement. Physicians performing the CVC recorded anatomical site, reason for insertion, and acute complications. The patients with catheters were followed until the catheters were removed based on radiographic evidence or hospital nursing records. ED charts and pharmacy records contributed variables of interest. A self-reported online survey provided physician experience information. Logistic regression was used to calculate the odds of an adverse outcome. Results: Physicians attempted 289 CVCs on 282 patients. An adverse outcome occurred in 57 attempts (19.7%, 95% confidence interval [CI] = 15.5 to 24.7), the most common being 31 unsuccessful placements (11%, 95% CI = 7.7 to 14.8). Patients with a history of end-stage renal disease (odds ratio [OR] = 3.54, 95% CI = 1.59 to 7.89), and central lines placed by operators with intermediate experience (OR = 2.26, 95% CI = 1.19 to 4.32), were most likely to encounter adverse events. Previously cited predictors such as body mass index (BMI), coagulopathy, and pulmonary hyperinflation were not significant in our final model. Conclusions: Acute adverse events occurred in approximately one-fifth of US-guided internal jugular central line attempts. The study identified both patient (history of end-stage renal disease) and physician (intermediate experience level) factors that are associated with acute adverse events.
AB - Background: Ultrasound (US) greatly facilitates cannulation of the internal jugular vein. Despite the ability to visualize the needle and anatomy, adverse events still occur. The authors hypothesized that the technique has limitations among certain patients and clinical scenarios. Objectives: The purpose of this study was to identify characteristics of adverse events surrounding US-guided central venous cannulation (CVC). Methods: The authors assembled a prospective observational cohort of emergency department (ED) patients undergoing consecutive internal jugular CVC with US. The primary outcome of interest was a composite of acute mechanical adverse events including hematoma, arterial cannulation, pneumothorax, and unsuccessful placement. Physicians performing the CVC recorded anatomical site, reason for insertion, and acute complications. The patients with catheters were followed until the catheters were removed based on radiographic evidence or hospital nursing records. ED charts and pharmacy records contributed variables of interest. A self-reported online survey provided physician experience information. Logistic regression was used to calculate the odds of an adverse outcome. Results: Physicians attempted 289 CVCs on 282 patients. An adverse outcome occurred in 57 attempts (19.7%, 95% confidence interval [CI] = 15.5 to 24.7), the most common being 31 unsuccessful placements (11%, 95% CI = 7.7 to 14.8). Patients with a history of end-stage renal disease (odds ratio [OR] = 3.54, 95% CI = 1.59 to 7.89), and central lines placed by operators with intermediate experience (OR = 2.26, 95% CI = 1.19 to 4.32), were most likely to encounter adverse events. Previously cited predictors such as body mass index (BMI), coagulopathy, and pulmonary hyperinflation were not significant in our final model. Conclusions: Acute adverse events occurred in approximately one-fifth of US-guided internal jugular central line attempts. The study identified both patient (history of end-stage renal disease) and physician (intermediate experience level) factors that are associated with acute adverse events.
KW - catheterization
KW - central venous
KW - emergency medicine
KW - interventional
KW - ultrasonography
UR - http://www.scopus.com/inward/record.url?scp=78649487675&partnerID=8YFLogxK
U2 - 10.1111/j.1553-2712.2010.00886.x
DO - 10.1111/j.1553-2712.2010.00886.x
M3 - Article
C2 - 21040106
AN - SCOPUS:78649487675
SN - 1069-6563
VL - 17
SP - 1055
EP - 1061
JO - Academic Emergency Medicine
JF - Academic Emergency Medicine
IS - 10
ER -