T1 - Resolution improvement by interpolation of charge sharing event position in 350μm pitch pixelated CdZnTe detectors
AU - Yin, Yongzhi
AU - Chen, Ximeng
AU - Wu, Heyu
AU - Komarov, Sergey
AU - Lee, Kuen
AU - Guo, Qingzhen
AU - Krawczynski, Henric
AU - Tai, Yuan Chuan
PY - 2011
Y1 - 2011
N2 - A coincidence detection system between 350μm pitch pixelated Cadmium Zinc Telluride (CdZnTe) detector and a LSO-based Inveon PET detector was set up to investigate the performance of using highly pixelated CdZnTe detector as a PET insert for sub-500μm resolution PET imaging applications. 20x20x5mm̂3 CdZnTe substrate was contacted with 350μm pitch pixels (250μm anode pixels with 100μm gap) and coplanar cathode. Based on the charge sharing measurement of the 350μm CdZnTe detector, we analyzed how charge sharing events from CdZnTe detector affect the PET image resolution. We recorded coincidence events between a central CdZnTe pixel and an Inveon LSO detector to image a NEMA NU4 Na-22 point source, which is 250μm in diameter and embedded in an acrylic cube. To interpolate the position of the charge sharing events between two neighbor pixels, we divided such events into five regions based on the ratio of signal amplitude of central pixel and neighbor pixels, and then reconstructed the PET image using events from different regions individually. Results show that the PET image resolution of coincidence events using the CdZnTe single-pixel photopeak events is 590μm FWHM, while the image resolution was decreased to 640μm FWHM if we included the charge sharing events. By interpolating the location of the charge sharing events, the reconstructed PET image resolution was improved from 640μm to 560μm. If we compensated the effective source dimension plus positron range, the image resolution was improved to 460μm FWHM. In a conclusion, the image resolution of an animal PET scanner can be improved to sub-500μm FWHM if we use 350μm pitch pixelated CdZnTe detector as a PET insert and integrate such device into the PET scanner.
AB - A coincidence detection system between 350μm pitch pixelated Cadmium Zinc Telluride (CdZnTe) detector and a LSO-based Inveon PET detector was set up to investigate the performance of using highly pixelated CdZnTe detector as a PET insert for sub-500μm resolution PET imaging applications. 20x20x5mm̂3 CdZnTe substrate was contacted with 350μm pitch pixels (250μm anode pixels with 100μm gap) and coplanar cathode. Based on the charge sharing measurement of the 350μm CdZnTe detector, we analyzed how charge sharing events from CdZnTe detector affect the PET image resolution. We recorded coincidence events between a central CdZnTe pixel and an Inveon LSO detector to image a NEMA NU4 Na-22 point source, which is 250μm in diameter and embedded in an acrylic cube. To interpolate the position of the charge sharing events between two neighbor pixels, we divided such events into five regions based on the ratio of signal amplitude of central pixel and neighbor pixels, and then reconstructed the PET image using events from different regions individually. Results show that the PET image resolution of coincidence events using the CdZnTe single-pixel photopeak events is 590μm FWHM, while the image resolution was decreased to 640μm FWHM if we included the charge sharing events. By interpolating the location of the charge sharing events, the reconstructed PET image resolution was improved from 640μm to 560μm. If we compensated the effective source dimension plus positron range, the image resolution was improved to 460μm FWHM. In a conclusion, the image resolution of an animal PET scanner can be improved to sub-500μm FWHM if we use 350μm pitch pixelated CdZnTe detector as a PET insert and integrate such device into the PET scanner.
UR - http://www.scopus.com/inward/record.url?scp=84863361383&partnerID=8YFLogxK
U2 - 10.1109/NSSMIC.2011.6152587
DO - 10.1109/NSSMIC.2011.6152587
M3 - Conference contribution
AN - SCOPUS:84863361383
SN - 9781467301183
T3 - IEEE Nuclear Science Symposium Conference Record
SP - 3263
EP - 3266
BT - 2011 IEEE Nuclear Science Symposium and Medical Imaging Conference, NSS/MIC 2011
PB - Institute of Electrical and Electronics Engineers Inc.
T2 - 2011 IEEE Nuclear Science Symposium and Medical Imaging Conference, NSS/MIC 2011
Y2 - 23 October 2011 through 29 October 2011
ER -