TY - JOUR
T1 - REPLACE DARE (death after replacement evaluation) score
T2 - Determinants of all-cause mortality after implantable device replacement or upgrade from the replace registry
AU - Replace Investigators
AU - Chung, Mina K.
AU - Holcomb, Richard G.
AU - Mittal, Suneet
AU - Steinberg, Jonathan S.
AU - Gleva, Marye J.
AU - Mela, Theofanie
AU - Uslan, Daniel Z.
AU - Mitchell, Kevin
AU - Poole, Jeanne E.
N1 - Publisher Copyright:
© 2014 American Heart Association, Inc.
PY - 2014/12/1
Y1 - 2014/12/1
N2 - Background: Identifying factors predictive of mortality may be important to decrease risk associated with cardiac implantable electrical device (CIED) replacement procedures. This study aimed to determine whether clinical factors and complications independently associate with death and to develop a mortality risk prediction tool after CIED replacement. Methods and Results: The prospective REPLACE Registry determined 6-month complication and mortality rates after CIED replacement with or without planned lead addition or revision. Vital status was collected. Kaplan-Meier survival and multivariable Cox proportional hazards regression analyses were performed to identify patient, procedural, or complication variables predictive of death. The REPLACE DARE (Death After Replacement Evaluation) Score was constructed using hazard ratios, reflecting relative risk contributions of each variable, combined into an additive mortality risk score equation. At 6 months, 70 of 1744 (4.0%) patients had died. Cox regression analysis found no significant association between major complications and death. However, recent heart failure admission, New York Heart Association class III/IV, antiarrhythmic drug use, cerebrovascular disease, and chronic kidney disease stage were independently associated with 6-month mortality. The REPLACE DARE Score was 2.0±1.4 in survivors versus 3.5±1.8 in nonsurvivors (P<0.001), with predictive receiver operating characteristic value=0.758 (P<0.001). Risk of death was 1.0% for DARE=0 and 55.6% for DARE=7. The hazard ratio was 1.8 for each change of 1 DARE unit. Conclusions: Comorbidities, but not complications, were significantly associated with mortality after CIED replacement. The REPLACE DARE Score is a novel tool that can identify patients with substantial mortality risk. Such patients should have the relative risk and benefit of their procedure considered carefully.
AB - Background: Identifying factors predictive of mortality may be important to decrease risk associated with cardiac implantable electrical device (CIED) replacement procedures. This study aimed to determine whether clinical factors and complications independently associate with death and to develop a mortality risk prediction tool after CIED replacement. Methods and Results: The prospective REPLACE Registry determined 6-month complication and mortality rates after CIED replacement with or without planned lead addition or revision. Vital status was collected. Kaplan-Meier survival and multivariable Cox proportional hazards regression analyses were performed to identify patient, procedural, or complication variables predictive of death. The REPLACE DARE (Death After Replacement Evaluation) Score was constructed using hazard ratios, reflecting relative risk contributions of each variable, combined into an additive mortality risk score equation. At 6 months, 70 of 1744 (4.0%) patients had died. Cox regression analysis found no significant association between major complications and death. However, recent heart failure admission, New York Heart Association class III/IV, antiarrhythmic drug use, cerebrovascular disease, and chronic kidney disease stage were independently associated with 6-month mortality. The REPLACE DARE Score was 2.0±1.4 in survivors versus 3.5±1.8 in nonsurvivors (P<0.001), with predictive receiver operating characteristic value=0.758 (P<0.001). Risk of death was 1.0% for DARE=0 and 55.6% for DARE=7. The hazard ratio was 1.8 for each change of 1 DARE unit. Conclusions: Comorbidities, but not complications, were significantly associated with mortality after CIED replacement. The REPLACE DARE Score is a novel tool that can identify patients with substantial mortality risk. Such patients should have the relative risk and benefit of their procedure considered carefully.
KW - Defibrillators, implantable
KW - Mortality
KW - Pacemakers
UR - http://www.scopus.com/inward/record.url?scp=84925545405&partnerID=8YFLogxK
U2 - 10.1161/CIRCEP.114.001671
DO - 10.1161/CIRCEP.114.001671
M3 - Article
C2 - 25221331
AN - SCOPUS:84925545405
SN - 1941-3149
VL - 7
SP - 1048
EP - 1056
JO - Circulation: Arrhythmia and Electrophysiology
JF - Circulation: Arrhythmia and Electrophysiology
IS - 6
ER -