TY - JOUR
T1 - Reexamining the Minimum Sweat Rate Requirement for Sweat Chloride Testing
AU - Omosule, Catherine L.
AU - Dietzen, Dennis J.
AU - Roper, Stephen M.
N1 - Publisher Copyright:
© 2023 Association for Diagnostics & Laboratory Medicine. All rights reserved.
PY - 2023/11/1
Y1 - 2023/11/1
N2 - Background: Guidelines for sweat chloride testing endorse a minimum sweat rate for reporting results. Bilateral sweat collection is recommended, but if both sites fail to meet the minimum rate (quantity not sufficient, QNS), the test should be repeated. In this study, we examine the correlation between sweat rate and sweat chloride concentration ([Cl-]), assess the accuracy of specimens collected at suboptimal rates, and investigate the use of pooled bilateral specimens for chloride measurement. Methods: Pearson correlation was employed to analyze the relationship between sweat rate and chloride concentration, [Cl-], in 674 macroduct collections. Weighted kappa was evaluated to determine cystic fibrosis (CF) diagnostic classification concordance for 18 tests with paired arms above vs below the minimum sweat rate. Deming regression was applied to compare [Cl-] from pooled bilateral specimens vs neat specimens in 27 collections with residual volume available after clinical testing. Results: Pearson correlation of sweat rate vs [Cl-] was minimal (r = -0.0735) across specimens with varying rates and [Cl-]. There was substantial agreement in CF diagnostic classification between arms for bilateral collections with discordant sweat rates. Regression analysis of [Cl-] in pooled vs nonpooled specimens revealed a slope of 0.984 and an intercept of 0.796. Conclusions: Negligible correlation of sweat rate and [Cl-] suggests the minimum sweat rate for macroduct collectors may be overly stringent. Reporting of [Cl-] in specimens with ≥10 μL (rate ≥0.3 μL/min) may reduce QNS rates without compromising diagnostic accuracy. Preliminary data suggests pooling of bilateral collections may be a feasible option to achieve the required volume for testing.
AB - Background: Guidelines for sweat chloride testing endorse a minimum sweat rate for reporting results. Bilateral sweat collection is recommended, but if both sites fail to meet the minimum rate (quantity not sufficient, QNS), the test should be repeated. In this study, we examine the correlation between sweat rate and sweat chloride concentration ([Cl-]), assess the accuracy of specimens collected at suboptimal rates, and investigate the use of pooled bilateral specimens for chloride measurement. Methods: Pearson correlation was employed to analyze the relationship between sweat rate and chloride concentration, [Cl-], in 674 macroduct collections. Weighted kappa was evaluated to determine cystic fibrosis (CF) diagnostic classification concordance for 18 tests with paired arms above vs below the minimum sweat rate. Deming regression was applied to compare [Cl-] from pooled bilateral specimens vs neat specimens in 27 collections with residual volume available after clinical testing. Results: Pearson correlation of sweat rate vs [Cl-] was minimal (r = -0.0735) across specimens with varying rates and [Cl-]. There was substantial agreement in CF diagnostic classification between arms for bilateral collections with discordant sweat rates. Regression analysis of [Cl-] in pooled vs nonpooled specimens revealed a slope of 0.984 and an intercept of 0.796. Conclusions: Negligible correlation of sweat rate and [Cl-] suggests the minimum sweat rate for macroduct collectors may be overly stringent. Reporting of [Cl-] in specimens with ≥10 μL (rate ≥0.3 μL/min) may reduce QNS rates without compromising diagnostic accuracy. Preliminary data suggests pooling of bilateral collections may be a feasible option to achieve the required volume for testing.
UR - http://www.scopus.com/inward/record.url?scp=85176509498&partnerID=8YFLogxK
U2 - 10.1093/jalm/jfad067
DO - 10.1093/jalm/jfad067
M3 - Article
C2 - 37757465
AN - SCOPUS:85176509498
SN - 2576-9456
VL - 8
SP - 1084
EP - 1091
JO - The journal of applied laboratory medicine
JF - The journal of applied laboratory medicine
IS - 6
ER -