TY - JOUR
T1 - Quantifying the effects of sleep on sensor-derived variables from upper limb accelerometry in people with and without upper limb impairment
AU - Miller, Allison E.
AU - Lang, Catherine E.
AU - Bland, Marghuretta D.
AU - Lohse, Keith R.
N1 - Publisher Copyright:
© The Author(s) 2024.
PY - 2024/12
Y1 - 2024/12
N2 - Background: Despite the promise of wearable sensors for both rehabilitation research and clinical care, these technologies pose significant burden on data collectors and analysts. Investigations of factors that may influence the wearable sensor data processing pipeline are needed to support continued use of these technologies in rehabilitation research and integration into clinical care settings. The purpose of this study was to investigate the effect of one such factor, sleep, on sensor-derived variables from upper limb accelerometry in people with and without upper limb impairment and across a two-day wearing period. Methods: This was a secondary analysis of data collected during a prospective, longitudinal cohort study (n = 127 individuals, 62 with upper limb impairment and 65 without). Participants wore a wearable sensor on each wrist for 48 h. Five upper limb sensor variables were calculated over the full wear period (sleep included) and with sleep time removed (sleep excluded): preferred time, non-preferred time, use ratio, non-preferred magnitude and its standard deviation. Linear mixed effects regression was used to quantify the effect of sleep on each sensor variable and determine if the effect differed between people with and without upper limb impairment and across a two-day wearing period. Results: There were significant differences between sleep included and excluded for the variables preferred time (p < 0.001), non-preferred time (p < 0.001), and non-preferred magnitude standard deviation (p = 0.001). The effect of sleep was significantly different between people with and without upper limb impairment for one variable, non-preferred magnitude (p = 0.02). The effect of sleep was not substantially different across wearing days for any of the variables. Conclusions: Overall, the effects of sleep on sensor-derived variables of upper limb accelerometry are small, similar between people with and without upper limb impairment and across a two-day wearing period, and can likely be ignored in most contexts. Ignoring the effect of sleep would simplify the data processing pipeline, facilitating the use of wearable sensors in both research and clinical practice.
AB - Background: Despite the promise of wearable sensors for both rehabilitation research and clinical care, these technologies pose significant burden on data collectors and analysts. Investigations of factors that may influence the wearable sensor data processing pipeline are needed to support continued use of these technologies in rehabilitation research and integration into clinical care settings. The purpose of this study was to investigate the effect of one such factor, sleep, on sensor-derived variables from upper limb accelerometry in people with and without upper limb impairment and across a two-day wearing period. Methods: This was a secondary analysis of data collected during a prospective, longitudinal cohort study (n = 127 individuals, 62 with upper limb impairment and 65 without). Participants wore a wearable sensor on each wrist for 48 h. Five upper limb sensor variables were calculated over the full wear period (sleep included) and with sleep time removed (sleep excluded): preferred time, non-preferred time, use ratio, non-preferred magnitude and its standard deviation. Linear mixed effects regression was used to quantify the effect of sleep on each sensor variable and determine if the effect differed between people with and without upper limb impairment and across a two-day wearing period. Results: There were significant differences between sleep included and excluded for the variables preferred time (p < 0.001), non-preferred time (p < 0.001), and non-preferred magnitude standard deviation (p = 0.001). The effect of sleep was significantly different between people with and without upper limb impairment for one variable, non-preferred magnitude (p = 0.02). The effect of sleep was not substantially different across wearing days for any of the variables. Conclusions: Overall, the effects of sleep on sensor-derived variables of upper limb accelerometry are small, similar between people with and without upper limb impairment and across a two-day wearing period, and can likely be ignored in most contexts. Ignoring the effect of sleep would simplify the data processing pipeline, facilitating the use of wearable sensors in both research and clinical practice.
KW - Accelerometry
KW - Breast cancer
KW - Fracture
KW - Multiple sclerosis
KW - Sleep
KW - Stroke
KW - Wearable sensors
UR - http://www.scopus.com/inward/record.url?scp=85194831385&partnerID=8YFLogxK
U2 - 10.1186/s12984-024-01384-z
DO - 10.1186/s12984-024-01384-z
M3 - Article
C2 - 38807245
AN - SCOPUS:85194831385
SN - 1743-0003
VL - 21
JO - Journal of NeuroEngineering and Rehabilitation
JF - Journal of NeuroEngineering and Rehabilitation
IS - 1
M1 - 86