TY - JOUR
T1 - Prospects for quantitative computed tomography imaging in the presence of foreign metal bodies using statistical image reconstruction
AU - Williamson, Jeffrey F.
AU - Whiting, Bruce R.
AU - Benac, Jasenka
AU - Murphy, Ryan J.
AU - Blaine, G. James
AU - O'Sullivan, Joseph A.
AU - Politte, David G.
AU - Snyder, Donald L.
PY - 2002/10
Y1 - 2002/10
N2 - X-ray computed tomography (CT) images of patients bearing metal intracavitary applicators or other metal foreign objects exhibit severe artifacts including streaks and aliasing. We have systematically evaluated via computer simulations the impact of scattered radiation, the polyenergetic spectrum, and measurement noise on the performance of three reconstruction algorithms: conventional filtered backprojection (FBP), deterministic iterative deblurring, and a new iterative algorithm, alternating minimization (AM), based on a CT detector model that includes noise, scatter, and polyenergetic spectra. Contrary to the dominant view of the literature, FBP streaking artifacts are due mostly to mismatches between FBP's simplified model of CT detector response and the physical process of signal acquisition. Artifacts on AM images are significantly mitigated as this algorithm substantially reduces detector-model mismatches. However, metal artifacts are reduced to acceptable levels only when prior knowledge of the metal object in the patient, including its pose, shape, and attenuation map, are used to constrain AM's iterations. AM image reconstruction, in combination with object-constrained CT to estimate the pose of metal objects in the patient, is a promising approach for effectively mitigating metal artifacts and making quantitative estimation of tissue attenuation coefficients a clinical possibility.
AB - X-ray computed tomography (CT) images of patients bearing metal intracavitary applicators or other metal foreign objects exhibit severe artifacts including streaks and aliasing. We have systematically evaluated via computer simulations the impact of scattered radiation, the polyenergetic spectrum, and measurement noise on the performance of three reconstruction algorithms: conventional filtered backprojection (FBP), deterministic iterative deblurring, and a new iterative algorithm, alternating minimization (AM), based on a CT detector model that includes noise, scatter, and polyenergetic spectra. Contrary to the dominant view of the literature, FBP streaking artifacts are due mostly to mismatches between FBP's simplified model of CT detector response and the physical process of signal acquisition. Artifacts on AM images are significantly mitigated as this algorithm substantially reduces detector-model mismatches. However, metal artifacts are reduced to acceptable levels only when prior knowledge of the metal object in the patient, including its pose, shape, and attenuation map, are used to constrain AM's iterations. AM image reconstruction, in combination with object-constrained CT to estimate the pose of metal objects in the patient, is a promising approach for effectively mitigating metal artifacts and making quantitative estimation of tissue attenuation coefficients a clinical possibility.
KW - Brachytherapy
KW - Filtered backprojection
KW - Metal artifact reduction
KW - Statistical image reconstruction
KW - X-ray transmission computed tomography
UR - http://www.scopus.com/inward/record.url?scp=0036798793&partnerID=8YFLogxK
U2 - 10.1118/1.1509443
DO - 10.1118/1.1509443
M3 - Article
C2 - 12408315
AN - SCOPUS:0036798793
SN - 0094-2405
VL - 29
SP - 2404
EP - 2418
JO - Medical physics
JF - Medical physics
IS - 10
ER -