TY - JOUR
T1 - Performance evaluation of the microPET P4
T2 - A PET system dedicated to animal imaging
AU - Tai, Y. C.
AU - Chatziioannou, A.
AU - Siegel, S.
AU - Young, J.
AU - Newport, D.
AU - Goble, R. N.
AU - Nutt, R. E.
AU - Cherry, S. R.
PY - 2001
Y1 - 2001
N2 - The microPET Primate 4-ring system (P4) is an animal PET tomograph with a 7.8 cm axial extent, a 19 cm diameter transaxial field of view (FOV) and a 22 cm animal port. The system is composed of 168 detector modules, each with an 8 × 8 array of 2.2 × 2.2 × 10 mm3 lutetium oxyorthosilicate crystals, arranged as 32 crystal rings 26 cm in diameter. The detector crystals are coupled to a Hamamatsu R5900-C8 PS-PMT via a 10 cm long optical fibre bundle. The detectors have a timing resolution of 3.2 ns, an average energy resolution of 26%, and an average intrinsic spatial resolution of 1.75 mm. The system operates in 3D mode without inter-plane septa, acquiring data in list mode. The reconstructed image spatial resolution ranges from 1.8 mm at the centre to 3 mm at 4 cm radial offset. The tomograph has a peak system sensitivity of 2.25% at the centre of the FOV with a 250-750 keV energy window. The noise equivalent count rate peaks at 100-290 kcps for representative object sizes. Images from two phantoms and three different types of laboratory animal demonstrate the advantage of the P4 system over the original prototype microPET, including its threefold improvement in sensitivity and a large axial FOV sufficient to image an entire mouse in a single bed position.
AB - The microPET Primate 4-ring system (P4) is an animal PET tomograph with a 7.8 cm axial extent, a 19 cm diameter transaxial field of view (FOV) and a 22 cm animal port. The system is composed of 168 detector modules, each with an 8 × 8 array of 2.2 × 2.2 × 10 mm3 lutetium oxyorthosilicate crystals, arranged as 32 crystal rings 26 cm in diameter. The detector crystals are coupled to a Hamamatsu R5900-C8 PS-PMT via a 10 cm long optical fibre bundle. The detectors have a timing resolution of 3.2 ns, an average energy resolution of 26%, and an average intrinsic spatial resolution of 1.75 mm. The system operates in 3D mode without inter-plane septa, acquiring data in list mode. The reconstructed image spatial resolution ranges from 1.8 mm at the centre to 3 mm at 4 cm radial offset. The tomograph has a peak system sensitivity of 2.25% at the centre of the FOV with a 250-750 keV energy window. The noise equivalent count rate peaks at 100-290 kcps for representative object sizes. Images from two phantoms and three different types of laboratory animal demonstrate the advantage of the P4 system over the original prototype microPET, including its threefold improvement in sensitivity and a large axial FOV sufficient to image an entire mouse in a single bed position.
UR - http://www.scopus.com/inward/record.url?scp=0034913087&partnerID=8YFLogxK
U2 - 10.1088/0031-9155/46/7/308
DO - 10.1088/0031-9155/46/7/308
M3 - Article
C2 - 11474929
AN - SCOPUS:0034913087
SN - 0031-9155
VL - 46
SP - 1845
EP - 1862
JO - Physics in medicine and biology
JF - Physics in medicine and biology
IS - 7
ER -