TY - JOUR
T1 - Outcomes and Safety of Percutaneous Aortic Valve Replacement
AU - Zajarias, Alan
AU - Cribier, Alain G.
PY - 2009/5/19
Y1 - 2009/5/19
N2 - The concept of transcatheter aortic valve replacement was developed with the goal of offering a therapeutic solution to patients with severe symptomatic aortic stenosis who are not considered good candidates for surgical valve replacement. Initial attempts were complicated by vascular access problems and lack of appropriate tools. With time and experience, early problems were solved and the concepts of valve sizing, valve positioning, and patient selection were defined. Technological improvements allowed the use of smaller arterial sheaths to decrease vascular trauma, special catheters to facilitate valve delivery, and treatments on the valve prostheses that would ensure longer durability. After 5 years, the number of transcatheter aortic valve replacements has grown significantly, and will likely continue as this technology becomes increasingly available. Currently, 2 valve models, the Edwards SAPIEN valve (Edwards Lifescience, Irvine, California) and the CoreValve ReValving system (CoreValve Inc., Irvine, California), have been used in over 4,000 cases worldwide for the treatment of symptomatic aortic stenosis. Midterm follow-up shows no evidence of restenosis or prosthetic valve dysfunction. Transfemoral and transapical delivery routes can be selected depending on the quality of vascular access and the type of prosthesis used. Randomized trials that are currently underway will confirm procedural safety and guide the applicability of this technology.
AB - The concept of transcatheter aortic valve replacement was developed with the goal of offering a therapeutic solution to patients with severe symptomatic aortic stenosis who are not considered good candidates for surgical valve replacement. Initial attempts were complicated by vascular access problems and lack of appropriate tools. With time and experience, early problems were solved and the concepts of valve sizing, valve positioning, and patient selection were defined. Technological improvements allowed the use of smaller arterial sheaths to decrease vascular trauma, special catheters to facilitate valve delivery, and treatments on the valve prostheses that would ensure longer durability. After 5 years, the number of transcatheter aortic valve replacements has grown significantly, and will likely continue as this technology becomes increasingly available. Currently, 2 valve models, the Edwards SAPIEN valve (Edwards Lifescience, Irvine, California) and the CoreValve ReValving system (CoreValve Inc., Irvine, California), have been used in over 4,000 cases worldwide for the treatment of symptomatic aortic stenosis. Midterm follow-up shows no evidence of restenosis or prosthetic valve dysfunction. Transfemoral and transapical delivery routes can be selected depending on the quality of vascular access and the type of prosthesis used. Randomized trials that are currently underway will confirm procedural safety and guide the applicability of this technology.
KW - aortic stenosis
KW - catheter
KW - stent
KW - survival
KW - valvuloplasty
UR - http://www.scopus.com/inward/record.url?scp=65149095001&partnerID=8YFLogxK
U2 - 10.1016/j.jacc.2008.11.059
DO - 10.1016/j.jacc.2008.11.059
M3 - Review article
C2 - 19442881
AN - SCOPUS:65149095001
SN - 0735-1097
VL - 53
SP - 1829
EP - 1836
JO - Journal of the American College of Cardiology
JF - Journal of the American College of Cardiology
IS - 20
ER -