TY - JOUR
T1 - On the accuracy and fitting of transversely isotropic material models
AU - Feng, Yuan
AU - Okamoto, Ruth J.
AU - Genin, Guy M.
AU - Bayly, Philip V.
N1 - Publisher Copyright:
© 2016 Elsevier Ltd.
PY - 2016/8/1
Y1 - 2016/8/1
N2 - Fiber reinforced structures are central to the form and function of biological tissues. Hyperelastic, transversely isotropic material models are used widely in the modeling and simulation of such tissues. Many of the most widely used models involve strain energy functions that include one or both pseudo-invariants (I4 or I5) to incorporate energy stored in the fibers. In a previous study we showed that both of these invariants must be included in the strain energy function if the material model is to reduce correctly to the well-known framework of transversely isotropic linear elasticity in the limit of small deformations. Even with such a model, fitting of parameters is a challenge. Here, by evaluating the relative roles of I4 and I5 in the responses to simple loadings, we identify loading scenarios in which previous models accounting for only one of these invariants can be expected to provide accurate estimation of material response, and identify mechanical tests that have special utility for fitting of transversely isotropic constitutive models. Results provide guidance for fitting of transversely isotropic constitutive models and for interpretation of the predictions of these models.
AB - Fiber reinforced structures are central to the form and function of biological tissues. Hyperelastic, transversely isotropic material models are used widely in the modeling and simulation of such tissues. Many of the most widely used models involve strain energy functions that include one or both pseudo-invariants (I4 or I5) to incorporate energy stored in the fibers. In a previous study we showed that both of these invariants must be included in the strain energy function if the material model is to reduce correctly to the well-known framework of transversely isotropic linear elasticity in the limit of small deformations. Even with such a model, fitting of parameters is a challenge. Here, by evaluating the relative roles of I4 and I5 in the responses to simple loadings, we identify loading scenarios in which previous models accounting for only one of these invariants can be expected to provide accurate estimation of material response, and identify mechanical tests that have special utility for fitting of transversely isotropic constitutive models. Results provide guidance for fitting of transversely isotropic constitutive models and for interpretation of the predictions of these models.
KW - Anisotropic material
KW - Biological material
KW - Constitutive behavior
KW - Transversely isotropic constitutive model
UR - http://www.scopus.com/inward/record.url?scp=84966440538&partnerID=8YFLogxK
U2 - 10.1016/j.jmbbm.2016.04.024
DO - 10.1016/j.jmbbm.2016.04.024
M3 - Article
C2 - 27136091
AN - SCOPUS:84966440538
SN - 1751-6161
VL - 61
SP - 554
EP - 566
JO - Journal of the Mechanical Behavior of Biomedical Materials
JF - Journal of the Mechanical Behavior of Biomedical Materials
ER -