TY - JOUR
T1 - Nuclear image-guided left ventricular pacing lead navigation feasibility of a new technique
AU - Ludwig, Daniel R.
AU - Menon, Prahlad G.
AU - Schwartzman, David
N1 - Publisher Copyright:
© 2015, Springer Science+Business Media New York.
PY - 2015/12/1
Y1 - 2015/12/1
N2 - Purpose: Current techniques for left ventricular (LV) lead implantation in patients with ischemic cardiomyopathy (ICM) typically underutilize information which is important for optimal lead location, including LV mechanical activation pattern and scar location. We sought to develop a technique in which this information, contained in single-photon emission computed tomographic (SPECT) images, could be integrated as to guide the electrophysiologist during the implantation procedure. Methods: Five ICM patients underwent SPECT as well as multidetector cardiac computed tomographic (MDCT) imaging prior to the LV lead implantation procedure. Images were merged to create a “fusion” image, in which the SPECT data were projected onto the anatomically accurate MDCT epicardial surface. The fusion image was registered to the operative field using the coronary veins, apparent on the MDCT image, as a fiducial system. After registration, LV lead implantation was guided by the fusion image using a commercial catheter navigation system. Results: Successful guidance was achieved in each patient, with minimal disturbance to standard workflow. Leads were implanted in late-activating, unscarred regions according to the fusion image, with locations corroborated by fluoroscopic and electrographic features. In regions where leads were contiguous to the phrenic nerve shown on the fusion image, pacing consistently demonstrated diaphragmatic stimulation. Conclusions: In this technical report, the description and feasibility of a new technique for SPECT image-guided LV pacing lead navigation is demonstrated. Prospective study will be required to confirm image precision and registration/navigation accuracy, as well as to demonstrate value relative to standard implantation techniques.
AB - Purpose: Current techniques for left ventricular (LV) lead implantation in patients with ischemic cardiomyopathy (ICM) typically underutilize information which is important for optimal lead location, including LV mechanical activation pattern and scar location. We sought to develop a technique in which this information, contained in single-photon emission computed tomographic (SPECT) images, could be integrated as to guide the electrophysiologist during the implantation procedure. Methods: Five ICM patients underwent SPECT as well as multidetector cardiac computed tomographic (MDCT) imaging prior to the LV lead implantation procedure. Images were merged to create a “fusion” image, in which the SPECT data were projected onto the anatomically accurate MDCT epicardial surface. The fusion image was registered to the operative field using the coronary veins, apparent on the MDCT image, as a fiducial system. After registration, LV lead implantation was guided by the fusion image using a commercial catheter navigation system. Results: Successful guidance was achieved in each patient, with minimal disturbance to standard workflow. Leads were implanted in late-activating, unscarred regions according to the fusion image, with locations corroborated by fluoroscopic and electrographic features. In regions where leads were contiguous to the phrenic nerve shown on the fusion image, pacing consistently demonstrated diaphragmatic stimulation. Conclusions: In this technical report, the description and feasibility of a new technique for SPECT image-guided LV pacing lead navigation is demonstrated. Prospective study will be required to confirm image precision and registration/navigation accuracy, as well as to demonstrate value relative to standard implantation techniques.
KW - Cardiac resynchronization therapy
KW - Computed tomography
KW - Heart failure
KW - Image guidance
KW - Pacing
KW - Single-photon emission computed tomography
UR - http://www.scopus.com/inward/record.url?scp=84947127649&partnerID=8YFLogxK
U2 - 10.1007/s10840-015-0046-9
DO - 10.1007/s10840-015-0046-9
M3 - Article
C2 - 26319647
AN - SCOPUS:84947127649
SN - 1383-875X
VL - 44
SP - 273
EP - 277
JO - Journal of Interventional Cardiac Electrophysiology
JF - Journal of Interventional Cardiac Electrophysiology
IS - 3
ER -