TY - GEN
T1 - No-gold-standard evaluation of quantitative imaging methods in the presence of correlated noise
AU - Liu, Ziping
AU - Li, Zekun
AU - Mhlanga, Joyce C.
AU - Siegel, Barry A.
AU - Jha, Abhinav K.
N1 - Funding Information:
Financial support for this work was provided by the National Institute of Biomedical Imaging and Bioengineering R01-EB031051, R56-EB028287, and R21-EB024647 (Trailblazer Award).
Publisher Copyright:
© 2022 SPIE. All rights reserved.
PY - 2022
Y1 - 2022
N2 - Objective evaluation of quantitative imaging (QI) methods with patient data is highly desirable, but is hindered by the lack or unreliability of an available gold standard. To address this issue, techniques that can evaluate QI methods without access to a gold standard are being actively developed. These techniques assume that the true and measured values are linearly related by a slope, bias, and Gaussian-distributed noise term, where the noise between measurements made by different methods is independent of each other. However, this noise arises in the process of measuring the same quantitative value, and thus can be correlated. To address this limitation, we propose a no-gold-standard evaluation (NGSE) technique that models this correlated noise by a multi-variate Gaussian distribution parameterized by a covariance matrix. We derive a maximum-likelihood-based approach to estimate the parameters that describe the relationship between the true and measured values, without any knowledge of the true values. We then use the estimated slopes and diagonal elements of the covariance matrix to compute the noise-To-slope ratio (NSR) to rank the QI methods on the basis of precision. The proposed NGSE technique was evaluated with multiple numerical experiments. Our results showed that the technique reliably estimated the NSR values and yielded accurate rankings of the considered methods for 83% of 160 trials. In particular, the technique correctly identified the most precise method for 97% of the trials. Overall, this study demonstrates the efficacy of the NGSE technique to accurately rank different QI methods when the correlated noise is present, and without access to any knowledge of the ground truth. The results motivate further validation of this technique with realistic simulation studies and patient data.
AB - Objective evaluation of quantitative imaging (QI) methods with patient data is highly desirable, but is hindered by the lack or unreliability of an available gold standard. To address this issue, techniques that can evaluate QI methods without access to a gold standard are being actively developed. These techniques assume that the true and measured values are linearly related by a slope, bias, and Gaussian-distributed noise term, where the noise between measurements made by different methods is independent of each other. However, this noise arises in the process of measuring the same quantitative value, and thus can be correlated. To address this limitation, we propose a no-gold-standard evaluation (NGSE) technique that models this correlated noise by a multi-variate Gaussian distribution parameterized by a covariance matrix. We derive a maximum-likelihood-based approach to estimate the parameters that describe the relationship between the true and measured values, without any knowledge of the true values. We then use the estimated slopes and diagonal elements of the covariance matrix to compute the noise-To-slope ratio (NSR) to rank the QI methods on the basis of precision. The proposed NGSE technique was evaluated with multiple numerical experiments. Our results showed that the technique reliably estimated the NSR values and yielded accurate rankings of the considered methods for 83% of 160 trials. In particular, the technique correctly identified the most precise method for 97% of the trials. Overall, this study demonstrates the efficacy of the NGSE technique to accurately rank different QI methods when the correlated noise is present, and without access to any knowledge of the ground truth. The results motivate further validation of this technique with realistic simulation studies and patient data.
KW - medical imaging
KW - no-gold-standard
KW - objective evaluation
KW - quantitative imaging
UR - http://www.scopus.com/inward/record.url?scp=85131898523&partnerID=8YFLogxK
U2 - 10.1117/12.2605762
DO - 10.1117/12.2605762
M3 - Conference contribution
C2 - 36465994
AN - SCOPUS:85131898523
T3 - Progress in Biomedical Optics and Imaging - Proceedings of SPIE
BT - Medical Imaging 2022
A2 - Mello-Thoms, Claudia R.
A2 - Mello-Thoms, Claudia R.
A2 - Taylor-Phillips, Sian
PB - SPIE
T2 - Medical Imaging 2022: Image Perception, Observer Performance, and Technology Assessment
Y2 - 21 March 2022 through 27 March 2022
ER -