TY - JOUR
T1 - Neutron activation of gadolinium for ion therapy
T2 - a Monte Carlo study of charged particle beams
AU - Van Delinder, Kurt W.
AU - Khan, Rao
AU - Gräfe, James L.
N1 - Publisher Copyright:
© 2020, The Author(s).
PY - 2020/12/1
Y1 - 2020/12/1
N2 - This study investigates the photon production from thermal neutron capture in a gadolinium (Gd) infused tumor as a result of secondary neutrons from particle therapy. Gadolinium contrast agents used in MRI are distributed within the tumor volume and can act as neutron capture agents. As a result of particle therapy, secondary neutrons are produced and absorbed by Gd in the tumor providing potential enhanced localized dose in addition to a signature photon spectrum that can be used to produce an image of the Gd enriched tumor. To investigate this imaging application, Monte Carlo (MC) simulations were performed for 10 different particles using a 5–10 cm spread out-Bragg peak (SOBP) centered on an 8 cm3, 3 mg/g Gd infused tumor. For a proton beam, 1.9 × 106 neutron captures per RBE weighted Gray Equivalent dose (GyE) occurred within the Gd tumor region. Antiprotons (P¯), negative pions (− π), and helium (He) ion beams resulted in 10, 17 and 1.3 times larger Gd neutron captures per GyE than protons, respectively. Therefore, the characteristic photon based spectroscopic imaging and secondary Gd dose enhancement could be viable and likely beneficial for these three particles.
AB - This study investigates the photon production from thermal neutron capture in a gadolinium (Gd) infused tumor as a result of secondary neutrons from particle therapy. Gadolinium contrast agents used in MRI are distributed within the tumor volume and can act as neutron capture agents. As a result of particle therapy, secondary neutrons are produced and absorbed by Gd in the tumor providing potential enhanced localized dose in addition to a signature photon spectrum that can be used to produce an image of the Gd enriched tumor. To investigate this imaging application, Monte Carlo (MC) simulations were performed for 10 different particles using a 5–10 cm spread out-Bragg peak (SOBP) centered on an 8 cm3, 3 mg/g Gd infused tumor. For a proton beam, 1.9 × 106 neutron captures per RBE weighted Gray Equivalent dose (GyE) occurred within the Gd tumor region. Antiprotons (P¯), negative pions (− π), and helium (He) ion beams resulted in 10, 17 and 1.3 times larger Gd neutron captures per GyE than protons, respectively. Therefore, the characteristic photon based spectroscopic imaging and secondary Gd dose enhancement could be viable and likely beneficial for these three particles.
UR - http://www.scopus.com/inward/record.url?scp=85089181222&partnerID=8YFLogxK
U2 - 10.1038/s41598-020-70429-9
DO - 10.1038/s41598-020-70429-9
M3 - Article
C2 - 32770174
AN - SCOPUS:85089181222
SN - 2045-2322
VL - 10
JO - Scientific reports
JF - Scientific reports
IS - 1
M1 - 13417
ER -