TY - JOUR
T1 - MRI vs CT-based 2D-3D auto-registration accuracy for quantifying shoulder motion using biplane video-radiography
AU - Akbari-Shandiz, Mohsen
AU - Lawrence, Rebekah L.
AU - Ellingson, Arin M.
AU - Johnson, Casey P.
AU - Zhao, Kristin D.
AU - Ludewig, Paula M.
N1 - Funding Information:
We gratefully acknowledge the generosity of the donors and their families. Funding was provided from the Minnesota Partnership for Biotechnology and Medical Genomics (MNP IF #14.02), University of Minnesota OVPR Infrastructure Grant, Institute for Engineering in Medicine Grant, NIH/NICHD K12HD073945, NIH/NICHD F31HD087069, NIH/NIBIB P41 EB015894, and the Foundation for Physical Therapy.
Funding Information:
We gratefully acknowledge the generosity of the donors and their families. Funding was provided from the Minnesota Partnership for Biotechnology and Medical Genomics (MNP IF #14.02), University of Minnesota OVPR Infrastructure Grant , Institute for Engineering in Medicine Grant , NIH/NICHD K12HD073945 , NIH/NICHD F31HD087069 , NIH/NIBIB P41 EB015894 , and the Foundation for Physical Therapy.
Publisher Copyright:
© 2018 Elsevier Ltd
PY - 2019/1/3
Y1 - 2019/1/3
N2 - Biplane 2D-3D registration approaches have been used for measuring 3D, in vivo glenohumeral (GH) joint kinematics. Computed tomography (CT) has become the gold standard for reconstructing 3D bone models, as it provides high geometric accuracy and similar tissue contrast to video-radiography. Alternatively, magnetic resonance imaging (MRI) would not expose subjects to radiation and provides the ability to add cartilage and other soft tissues to the models. However, the accuracy of MRI-based 2D-3D registration for quantifying glenohumeral kinematics is unknown. We developed an automatic 2D-3D registration program that works with both CT- and MRI-based image volumes for quantifying joint motions. The purpose of this study was to use the proposed 2D-3D auto-registration algorithm to describe the humerus and scapula tracking accuracy of CT- and MRI-based registration relative to radiostereometric analysis (RSA) during dynamic biplanar video-radiography. The GH kinematic accuracy (RMS error) was 0.6–1.0 mm and 0.6–2.2° for the CT-based registration and 1.4–2.2 mm and 1.2–2.6° for MRI-based registration. Higher kinematic accuracy of CT-based registration was expected as MRI provides lower spatial resolution and bone contrast as compared to CT and suffers from spatial distortions. However, the MRI-based registration is within an acceptable accuracy for many clinical research questions.
AB - Biplane 2D-3D registration approaches have been used for measuring 3D, in vivo glenohumeral (GH) joint kinematics. Computed tomography (CT) has become the gold standard for reconstructing 3D bone models, as it provides high geometric accuracy and similar tissue contrast to video-radiography. Alternatively, magnetic resonance imaging (MRI) would not expose subjects to radiation and provides the ability to add cartilage and other soft tissues to the models. However, the accuracy of MRI-based 2D-3D registration for quantifying glenohumeral kinematics is unknown. We developed an automatic 2D-3D registration program that works with both CT- and MRI-based image volumes for quantifying joint motions. The purpose of this study was to use the proposed 2D-3D auto-registration algorithm to describe the humerus and scapula tracking accuracy of CT- and MRI-based registration relative to radiostereometric analysis (RSA) during dynamic biplanar video-radiography. The GH kinematic accuracy (RMS error) was 0.6–1.0 mm and 0.6–2.2° for the CT-based registration and 1.4–2.2 mm and 1.2–2.6° for MRI-based registration. Higher kinematic accuracy of CT-based registration was expected as MRI provides lower spatial resolution and bone contrast as compared to CT and suffers from spatial distortions. However, the MRI-based registration is within an acceptable accuracy for many clinical research questions.
KW - Automatic 2D-3D registration
KW - Glenohumeral kinematics
KW - Motion tracking accuracy
KW - Radiostereometric analysis (RSA)
KW - Shoulder motion tracking
UR - http://www.scopus.com/inward/record.url?scp=85055641094&partnerID=8YFLogxK
U2 - 10.1016/j.jbiomech.2018.09.019
DO - 10.1016/j.jbiomech.2018.09.019
M3 - Article
C2 - 30385001
AN - SCOPUS:85055641094
SN - 0021-9290
VL - 82
SP - 375
EP - 380
JO - Journal of Biomechanics
JF - Journal of Biomechanics
ER -