TY - JOUR
T1 - Meta-Analysis Comparing Drug-Coated Balloon Versus Plain Old Balloon Angioplasty for In-Stent Restenosis of Coronary Arteries
AU - Shaikh, Safia
AU - Hamza, Mohammad
AU - Upreti, Prakash
AU - Akkawi, Mohammad
AU - Rajak, Kripa
AU - Haider, Mobeen Zaka
AU - Kumar, Nomesh
AU - Turkmani, Mustafa
AU - Kathawa, Fadi
AU - Basit, Salman Abdul
AU - Bahar, Yasemin
AU - Fakhra, Sadaf
AU - Sattar, Yasar
AU - Alraies, M. Chadi
N1 - Publisher Copyright:
© 2024
PY - 2024/10/15
Y1 - 2024/10/15
N2 - Despite the advent of newer stents, in-stent restenosis has been a persistent and formidable challenge. Trials have demonstrated the superiority of drug-coated balloons over plain old balloon angioplasty. A recent AGENT IDE PRESTO (Prevention of REStenosis with Tranilast and its Outcomes) trial highlighted the need for a more comprehensive understanding; therefore, we conducted a meta-analysis to elucidate their respective clinical outcomes. A literature search was conducted by 2 investigators (SS and MH) using MEDLINE (EMBASE and PubMed) using a systematic search strategy by Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) until November 1, 2023. CRAN-R software was used for statistical analysis. The quality assessment was performed using the Cochrane Risk of Bias tool (Supplementary Table 5). We included 6 studies with a total of 1,171 patients. Our analysis showed decreased odds of multiple outcomes with statistically significant results, including target vessel revascularization (odds ratio [OR] 0.33, confidence interval [CI] 0.19 to 0.57), target vessel failure (OR 0.30, CI 0.09 to 0.99), target lesion revascularization (OR 0.22, CI 0.10 to 0.46), restenosis (OR 0.1343, CI 0.06 to 0.27), and major adverse cardiac events (OR 0.2 CI 0.12 to 0.37). Although myocardial infraction and all-cause mortality showed decreased odds with all-cause mortality at 0.8 (95% CI 0.363 to 2.09), and myocardial infarction at 0.6 (95% CI 0.0349 to 1.07), the reductions did not reach statistical significance. Our analysis by scrutinizing 6 randomized controlled trials favored drug-coated balloons over plain old balloon angioplasty. However, extensive research for deeper understanding cannot be overemphasized.
AB - Despite the advent of newer stents, in-stent restenosis has been a persistent and formidable challenge. Trials have demonstrated the superiority of drug-coated balloons over plain old balloon angioplasty. A recent AGENT IDE PRESTO (Prevention of REStenosis with Tranilast and its Outcomes) trial highlighted the need for a more comprehensive understanding; therefore, we conducted a meta-analysis to elucidate their respective clinical outcomes. A literature search was conducted by 2 investigators (SS and MH) using MEDLINE (EMBASE and PubMed) using a systematic search strategy by Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) until November 1, 2023. CRAN-R software was used for statistical analysis. The quality assessment was performed using the Cochrane Risk of Bias tool (Supplementary Table 5). We included 6 studies with a total of 1,171 patients. Our analysis showed decreased odds of multiple outcomes with statistically significant results, including target vessel revascularization (odds ratio [OR] 0.33, confidence interval [CI] 0.19 to 0.57), target vessel failure (OR 0.30, CI 0.09 to 0.99), target lesion revascularization (OR 0.22, CI 0.10 to 0.46), restenosis (OR 0.1343, CI 0.06 to 0.27), and major adverse cardiac events (OR 0.2 CI 0.12 to 0.37). Although myocardial infraction and all-cause mortality showed decreased odds with all-cause mortality at 0.8 (95% CI 0.363 to 2.09), and myocardial infarction at 0.6 (95% CI 0.0349 to 1.07), the reductions did not reach statistical significance. Our analysis by scrutinizing 6 randomized controlled trials favored drug-coated balloons over plain old balloon angioplasty. However, extensive research for deeper understanding cannot be overemphasized.
KW - coronary arteries
KW - drug-coated balloon
KW - in-stent restenosis
KW - plain old balloon angioplasty
UR - http://www.scopus.com/inward/record.url?scp=85202483462&partnerID=8YFLogxK
U2 - 10.1016/j.amjcard.2024.07.015
DO - 10.1016/j.amjcard.2024.07.015
M3 - Review article
C2 - 39029724
AN - SCOPUS:85202483462
SN - 0002-9149
VL - 229
SP - 22
EP - 27
JO - American Journal of Cardiology
JF - American Journal of Cardiology
ER -