T1 - Mechanical ventilation with or without daily changes of in-line suction catheters
AU - Kollef, Marin H.
AU - Prentice, Donna
AU - Shapiro, Steven D.
AU - Fraser, Victoria J.
AU - Silver, Patricia
AU - Trovillion, Ellen
AU - Weilitz, Pamela
AU - Von Harz, Benjamin
AU - John, Robert St
PY - 1997/1/1
Y1 - 1997/1/1
N2 - The purpose of this study was to determine the safety and cost- effectiveness of not routinely changing in-line suction catheters for patients requiting mechanical ventilation. Patients were randomly assigned to receive either no routine in-line suction catheter changes (n = 258) or in- line suction catheter changes every 24 h (n = 263). The main outcome measure was the incidence of ventilator-associated pneumonia. Other outcomes evaluated included hospital mortality, acquired organ system derangements, duration of mechanical ventilation, lengths of intensive care and hospital stay, and the cost for in-line suction catheters. Ventilator-associated pneumonia was seen in 38 patients (14.7%) receiving no routine in-line suction catheter changes and in 39 patients (14.8%) receiving in-line suction catheter changes every 24 h (relative risk, 0.99; 95% CI, 0.66 to 1.50). No statistically significant differences for hospital mortality, lengths of stay, the number of acquired organ system derangements, death in patients with ventilator-associated pneumonia, or mortality directly attributed to ventilator-associated pneumonia were found between the two treatment groups. Patients receiving in-line suction catheter changes every 24 h had 1,224 catheter changes costing a total of $11,016; patients receiving no routine in-line suction catheter changes had a total of 93 catheter changes costing $837. Our findings suggest that the elimination of routine in-line suction catheter changes is safe and can reduce the costs associated with providing mechanical ventilation.
AB - The purpose of this study was to determine the safety and cost- effectiveness of not routinely changing in-line suction catheters for patients requiting mechanical ventilation. Patients were randomly assigned to receive either no routine in-line suction catheter changes (n = 258) or in- line suction catheter changes every 24 h (n = 263). The main outcome measure was the incidence of ventilator-associated pneumonia. Other outcomes evaluated included hospital mortality, acquired organ system derangements, duration of mechanical ventilation, lengths of intensive care and hospital stay, and the cost for in-line suction catheters. Ventilator-associated pneumonia was seen in 38 patients (14.7%) receiving no routine in-line suction catheter changes and in 39 patients (14.8%) receiving in-line suction catheter changes every 24 h (relative risk, 0.99; 95% CI, 0.66 to 1.50). No statistically significant differences for hospital mortality, lengths of stay, the number of acquired organ system derangements, death in patients with ventilator-associated pneumonia, or mortality directly attributed to ventilator-associated pneumonia were found between the two treatment groups. Patients receiving in-line suction catheter changes every 24 h had 1,224 catheter changes costing a total of $11,016; patients receiving no routine in-line suction catheter changes had a total of 93 catheter changes costing $837. Our findings suggest that the elimination of routine in-line suction catheter changes is safe and can reduce the costs associated with providing mechanical ventilation.
UR - http://www.scopus.com/inward/record.url?scp=0030855197&partnerID=8YFLogxK
U2 - 10.1164/ajrccm.156.2.9612083
DO - 10.1164/ajrccm.156.2.9612083
M3 - Article
C2 - 9279225
AN - SCOPUS:0030855197
SN - 1073-449X
VL - 156
SP - 466
EP - 472
JO - American journal of respiratory and critical care medicine
JF - American journal of respiratory and critical care medicine
IS - 2 I
ER -