TY - JOUR
T1 - Management of rheumatoid arthritis of the elbow with a convertible total elbow arthroplasty
AU - Strelzow, Jason A.
AU - Frank, Tym
AU - Chan, Kevin
AU - Athwal, George S.
AU - Faber, Kenneth J.
AU - King, Graham J.W.
N1 - Publisher Copyright:
© 2019 Journal of Shoulder and Elbow Surgery Board of Trustees
PY - 2019/11
Y1 - 2019/11
N2 - Background: Total elbow arthroplasty (TEA) is commonly performed in patients with rheumatoid arthritis (RA). The purpose of this study was to compare outcomes and complications of unlinked and linked TEA using a convertible system in patients with RA. Methods: All patients with RA who underwent TEA at a single center with a minimum of 2 years' follow-up were reviewed. Demographic information, patient-reported outcome scores, functional outcome assessments, and radiographic parameters were evaluated at most recent follow-up. Results: We evaluated 82 patients (27 with unlinked TEA and 55 with linked TEA) with RA. The mean age at surgery was 61 ± 10 years, with a mean follow-up period of 6 ± 4 years. Demographic characteristics were similar between groups, with the exception of longer follow-up in the unlinked group (8 years vs. 5 years, P = .001). No differences in range of motion were noted. Elbow strength was similar other than pronation strength (74% ± 8% for unlinked vs. 100% ± 8% for linked, P = .03). The mean Mayo Elbow Performance Index was 83 ± 16; Patient Rated Elbow Evaluation score, 15 ± 18; and QuickDASH (short version of the Disabilities of the Arm, Shoulder and Hand questionnaire) score, 34 ± 20. No differences in the rates of reoperation (17% vs. 24%, P = .4), complications (32% vs. 31%, P = .4), or revisions (13% vs. 17%, P = .3) were found between unlinked and linked devices. Four patients with instability, all with unlinked designs, underwent revision to a linked design. Four patients, all with linked designs, underwent revision for aseptic loosening of smooth short-stem ulnar components. Conclusion: TEA using a convertible implant design provides good patient-reported outcomes at mid-term follow-up in patients with RA. Our study was unable to detect a difference in the use of either unlinked or linked implant designs; further large comparison trials are needed.
AB - Background: Total elbow arthroplasty (TEA) is commonly performed in patients with rheumatoid arthritis (RA). The purpose of this study was to compare outcomes and complications of unlinked and linked TEA using a convertible system in patients with RA. Methods: All patients with RA who underwent TEA at a single center with a minimum of 2 years' follow-up were reviewed. Demographic information, patient-reported outcome scores, functional outcome assessments, and radiographic parameters were evaluated at most recent follow-up. Results: We evaluated 82 patients (27 with unlinked TEA and 55 with linked TEA) with RA. The mean age at surgery was 61 ± 10 years, with a mean follow-up period of 6 ± 4 years. Demographic characteristics were similar between groups, with the exception of longer follow-up in the unlinked group (8 years vs. 5 years, P = .001). No differences in range of motion were noted. Elbow strength was similar other than pronation strength (74% ± 8% for unlinked vs. 100% ± 8% for linked, P = .03). The mean Mayo Elbow Performance Index was 83 ± 16; Patient Rated Elbow Evaluation score, 15 ± 18; and QuickDASH (short version of the Disabilities of the Arm, Shoulder and Hand questionnaire) score, 34 ± 20. No differences in the rates of reoperation (17% vs. 24%, P = .4), complications (32% vs. 31%, P = .4), or revisions (13% vs. 17%, P = .3) were found between unlinked and linked devices. Four patients with instability, all with unlinked designs, underwent revision to a linked design. Four patients, all with linked designs, underwent revision for aseptic loosening of smooth short-stem ulnar components. Conclusion: TEA using a convertible implant design provides good patient-reported outcomes at mid-term follow-up in patients with RA. Our study was unable to detect a difference in the use of either unlinked or linked implant designs; further large comparison trials are needed.
KW - convertible design
KW - elbow replacement
KW - Level III
KW - outcomes
KW - Retrospective Cohort Design
KW - rheumatoid arthritis
KW - Total elbow arthroplasty
KW - Treatment Study
UR - https://www.scopus.com/pages/publications/85073552439
U2 - 10.1016/j.jse.2019.07.029
DO - 10.1016/j.jse.2019.07.029
M3 - Article
C2 - 31630751
AN - SCOPUS:85073552439
SN - 1058-2746
VL - 28
SP - 2205
EP - 2214
JO - Journal of Shoulder and Elbow Surgery
JF - Journal of Shoulder and Elbow Surgery
IS - 11
ER -