TY - JOUR
T1 - Mammography in 53,803 women from the New Hampshire mammography network
AU - Poplack, S. P.
AU - Tosteson, A. N.
AU - Grove, M. R.
AU - Wells, W. A.
AU - Carney, P. A.
PY - 2000/1/1
Y1 - 2000/1/1
N2 - PURPOSE: To describe measures of mammography performance in a geographically defined population and evaluate the interpreter's use of the Breast Imaging Reporting and Data System (BI-RADS). MATERIALS AND METHODS: Mammographic data from 47,651 screening and 6, 152 diagnostic examinations from November 1, 1996, to October 31, 1997, were linked to 1,572 pathologic results. Mammographic outcomes were based on BI-RADS assessments and recommendations reported by the interpreting radiologist. The consistency of BI-RADS recommendations was evaluated. RESULTS: Screening mammography had a sensitivity of 72.4% (95% CI: 66.4%, 78.4%), specificity of 97.3% (95% CI: 97.25%, 97.4%), and positive predictive value of 10.6% (9.5% CI: 9.1%, 12.2%). Diagnostic mammography had higher sensitivity, 78.1% (95% CI: 71.9%, 84.3%); lower specificity, 89.3% (95% CI: 88.5%, 90.1%); and better positive predictive value, 17.1% (95% CI: 14.5%, 19.8%). The cancer detection rate with screening mammography was 3.3 per 1,000 women, with a biopsy yield of 22.4%, whereas the interval cancer rate was 1.2 per 1,000. Nearly 80% of screening-detected invasive malignancies were node negative. The recall rate for screening mammography was 8.3%. Ultrasonography was used in 3.5% of screening and 17.5% of diagnostic examinations. BI-RADS recommendations were generally consistent, except for probably benign assessments. CONCLUSION: The sensitivity of screening mammography in this population-based sample is lower than expected, although other performance indicators are commendable. BI-RADS 'probably benign' assessments are commonly misused.
AB - PURPOSE: To describe measures of mammography performance in a geographically defined population and evaluate the interpreter's use of the Breast Imaging Reporting and Data System (BI-RADS). MATERIALS AND METHODS: Mammographic data from 47,651 screening and 6, 152 diagnostic examinations from November 1, 1996, to October 31, 1997, were linked to 1,572 pathologic results. Mammographic outcomes were based on BI-RADS assessments and recommendations reported by the interpreting radiologist. The consistency of BI-RADS recommendations was evaluated. RESULTS: Screening mammography had a sensitivity of 72.4% (95% CI: 66.4%, 78.4%), specificity of 97.3% (95% CI: 97.25%, 97.4%), and positive predictive value of 10.6% (9.5% CI: 9.1%, 12.2%). Diagnostic mammography had higher sensitivity, 78.1% (95% CI: 71.9%, 84.3%); lower specificity, 89.3% (95% CI: 88.5%, 90.1%); and better positive predictive value, 17.1% (95% CI: 14.5%, 19.8%). The cancer detection rate with screening mammography was 3.3 per 1,000 women, with a biopsy yield of 22.4%, whereas the interval cancer rate was 1.2 per 1,000. Nearly 80% of screening-detected invasive malignancies were node negative. The recall rate for screening mammography was 8.3%. Ultrasonography was used in 3.5% of screening and 17.5% of diagnostic examinations. BI-RADS recommendations were generally consistent, except for probably benign assessments. CONCLUSION: The sensitivity of screening mammography in this population-based sample is lower than expected, although other performance indicators are commendable. BI-RADS 'probably benign' assessments are commonly misused.
KW - Breast neoplasms, radiography
KW - Cancer screening
KW - Diagnostic radiology, observer performance
UR - http://www.scopus.com/inward/record.url?scp=0033677515&partnerID=8YFLogxK
U2 - 10.1148/radiology.217.3.r00dc33832
DO - 10.1148/radiology.217.3.r00dc33832
M3 - Article
C2 - 11110951
AN - SCOPUS:0033677515
SN - 0033-8419
VL - 217
SP - 832
EP - 840
JO - Radiology
JF - Radiology
IS - 3
ER -