Looped versus single-stranded flexor tendon repairs: A cadaveric mechanical study

Ryan P. Calfee, Sean Boone, Jeffrey G. Stepan, Daniel A. Osei, Stavros Thomopoulos, Martin I. Boyer

Research output: Contribution to journalArticlepeer-review

8 Scopus citations

Abstract

Purpose To compare the tensile properties of 4-strand modified Kessler flexor tendon repairs using a looped or single-stranded suture. Methods We evaluated the mechanical properties of 4-strand Kessler zone II core suture repairs using either looped or single-stranded suture in human flexor digitorum profundus and flexor pollicis longus tendons. Forty repairs were performed on tendons from bilateral cadaveric hands: 20 matched tendons were divided into equal groups of 3-0 looped and 3-0 single-strand repairs and 20 additional matched tendons were divided into equal groups of 4-0 looped and 4-0 single-strand repairs. Repaired tendons were tested in uniaxial tension to failure to determine mechanical properties and failure modes. Data were analyzed to determine the effect of repair type (ie, looped vs single-stranded) for each suture caliber (ie, 3-0 and 4-0). Results Single-strand repairs with 3-0 suture demonstrated a significantly greater maximum load to failure and a significantly higher force at 2-mm gap compared with repairs with looped 3-0 suture. All 8 looped repairs with 3-0 suture failed by suture pullout whereas 7 of 8 repairs with 3-0 single-stranded suture failed by suture breakage. The mechanical properties of looped versus single-stranded repairs with 4-0 caliber suture were not statistically different. Repairs with 4-0 caliber suture failed by suture breakage in 8 of 10 single-strand repairs and failed by suture pullout in 6 of 10 repairs with looped suture. Conclusions In a time-0 ex vivo human cadaveric core suture model, the mechanical properties of a 4-strand repair using 3-0 single-stranded suture were significantly better than the same 4-strand repair performed with looped suture. Clinical relevance Four-strand flexor tendon repairs with 3-0 suture are mechanically superior when performed with single-strand suture versus looped suture.

Original languageEnglish
Article number54414
Pages (from-to)958-962.e1
JournalJournal of Hand Surgery
Volume40
Issue number5
DOIs
StatePublished - May 1 2015

Keywords

  • Flexor tendon
  • looped
  • repair
  • zone II

Fingerprint

Dive into the research topics of 'Looped versus single-stranded flexor tendon repairs: A cadaveric mechanical study'. Together they form a unique fingerprint.

Cite this