Lessons learned from data logging in a multicenter clinical trial using a late-generation implantable cardioverter-defibrillator

Mark A. Wood, Bruce S. Stambler, Ralph J. Damiano, Patricia Greenway, Kenneth A. Ellenbogen

Research output: Contribution to journalArticlepeer-review

57 Scopus citations

Abstract

Objectives. This study examined patterns of implantable cardioverter-defibrillator use as documented by data logging. Background. Implantable cardioverter-defibrillators are accepted therapy for malignant ventricular tachyarrhythmias; however, relatively little is known about their patterns of use. Incorporation of data-storage capacities into these devices provides insight into long-term defibrillator function. Methods. Stored data-logging information was retrieved from 401 implanted cardioverter-defibrillators in 393 patients over an average of 303 days of follow-up. Results. A total of 91,443 detections were recorded in 299 patients. One hundred-six patients (26%) had detections due to supraventricular tachycardias, electrical noise or other causes, resulting in inappropriate therapy delivery to 92 patients (23%). Two hundred eighty-one patients recorded 66,276 episodes of ventricular tachycardia or ventricular fibrillation. Of these, 74.4% episodes terminated spontaneously without any delivered therapy, 22.1% terminated after antitachycardia pacing, and 1.7% terminated after shock therapy. Antitachycardia pacing was activated without formal testing in 47% of all patients receiving this therapy and was successful in 96% of all episodes receiving this therapy. Acceleration of tachycardia to shock therapy occurred in 1.3% of all episodes and in 30.5% of patients receiving antitachycardia pacing. Thirty-four patients (8.7%) died during follow-up. Mortality was associated with patient age, heart failure functional class at implantation and frequency of shocks received during follow-up (all p ≤ 0.05). Conclusions. Most ventricular tachyarrhythmia detections by this noncommitted implantable cardioverter-defibrillator resolve spontaneously, whereas the majority receiving therapy can be treated with antitachycardia pacing. Mortality after implantable cardioverter-defibrillator implantation is associated with age, heart failure class and frequency of shocks received during follow-up. Data-logging capabilities provide valuable insights into the patterns of defibriliator use.

Original languageEnglish
Pages (from-to)1692-1699
Number of pages8
JournalJournal of the American College of Cardiology
Volume24
Issue number7
DOIs
StatePublished - Dec 1994

Fingerprint

Dive into the research topics of 'Lessons learned from data logging in a multicenter clinical trial using a late-generation implantable cardioverter-defibrillator'. Together they form a unique fingerprint.

Cite this