TY - JOUR
T1 - Isotope dilution gas chromatographic-mass spectrometric measurement of tricyclic antidepressant drugs. Utility of the 4-carbethoxyhexafluorobutyryl derivatives of secondary amines
AU - Way, Barbara A.
AU - Stickle, Douglas
AU - Mitchell, Mary E.
AU - Koenig, John W.
AU - Turk, John
PY - 1998/9
Y1 - 1998/9
N2 - Stable isotope dilution gas chromatographic-mass spectrometric (GC-MS) measurement of tricyclic antidepressants (TCA) is a useful alternative to high-performance liquid chromatography (HPLC) methods when interfering substances prevent accurate quantitation by HPLC. For satisfactory GC-MS analysis, secondary amine TCA must be derivatized. Commonly employed trifluoroacetyl and heptafluorobutyryl derivatives are relatively unstable and cause rapid deterioration of capillary GC columns. Therefore we examined 4-carbethoxyhexafluorobutyryl chloride (CHFB-Cl) as an alternative derivatizing agent and developed a stable isotope dilution GC-MS method employing ring-labeled [2H4]-desipramine and [2H4]-imipramine internal standards, which permits measurement of desipramine, nortriptyline, imipramine, and amitriptyline in plasma samples containing one or all of these analytes. The GC-MS assay is linear for each analyte from the lower limit of quantitation (25 ng/mL) up to 1500 ng/mL and correlates well with HPLC measurements. The GC-MS analytic coefficient of variation was 9.7 ± 1.3% for all analytes considered together. Although interferences are observed in the HPLC assay, thioridazine, perphenazine, cyclobenzaprine, and norcyclobenzaprine do not interfere with GC-MS measurements of the TCA examined here. The stability of the CHFB derivative of secondary amine TCA was found to be superior to that of the trifluoroacetyl derivatives of these compounds.
AB - Stable isotope dilution gas chromatographic-mass spectrometric (GC-MS) measurement of tricyclic antidepressants (TCA) is a useful alternative to high-performance liquid chromatography (HPLC) methods when interfering substances prevent accurate quantitation by HPLC. For satisfactory GC-MS analysis, secondary amine TCA must be derivatized. Commonly employed trifluoroacetyl and heptafluorobutyryl derivatives are relatively unstable and cause rapid deterioration of capillary GC columns. Therefore we examined 4-carbethoxyhexafluorobutyryl chloride (CHFB-Cl) as an alternative derivatizing agent and developed a stable isotope dilution GC-MS method employing ring-labeled [2H4]-desipramine and [2H4]-imipramine internal standards, which permits measurement of desipramine, nortriptyline, imipramine, and amitriptyline in plasma samples containing one or all of these analytes. The GC-MS assay is linear for each analyte from the lower limit of quantitation (25 ng/mL) up to 1500 ng/mL and correlates well with HPLC measurements. The GC-MS analytic coefficient of variation was 9.7 ± 1.3% for all analytes considered together. Although interferences are observed in the HPLC assay, thioridazine, perphenazine, cyclobenzaprine, and norcyclobenzaprine do not interfere with GC-MS measurements of the TCA examined here. The stability of the CHFB derivative of secondary amine TCA was found to be superior to that of the trifluoroacetyl derivatives of these compounds.
UR - https://www.scopus.com/pages/publications/0031658506
U2 - 10.1093/jat/22.5.374
DO - 10.1093/jat/22.5.374
M3 - Article
C2 - 9737332
AN - SCOPUS:0031658506
SN - 0146-4760
VL - 22
SP - 374
EP - 382
JO - Journal of Analytical Toxicology
JF - Journal of Analytical Toxicology
IS - 5
ER -