TY - JOUR
T1 - Investigation of neovascularization in three-dimensional porous scaffolds in vivo by a combination of multiscale photoacoustic microscopy and optical coherence tomography
AU - Cai, Xin
AU - Zhang, Yu
AU - Li, Li
AU - Choi, Sung Wook
AU - MacEwan, Matthew R.
AU - Yao, Junjie
AU - Kim, Chulhong
AU - Xia, Younan
AU - Wang, Lihong V.
PY - 2013/3/1
Y1 - 2013/3/1
N2 - It is a grand challenge to visualize and assess in vivo neovascularization in a three-dimensional (3D) scaffold noninvasively, together with high spatial resolution and deep penetration depth. Here we used multiscale photoacoustic microscopy (PAM), including acoustic-resolution PAM (AR-PAM) and optical-resolution PAM (OR-PAM), to chronically monitor neovascularization in an inverse opal scaffold implanted in a mouse model up to 6 weeks by taking advantage of the optical absorption contrast intrinsic to hemoglobin molecules in red blood cells. By combining with optical coherence tomography (OCT) based on optical scattering contrast, we also demonstrated the capability to simultaneously image and analyze the vasculature and the scaffold in the same mouse. The hybrid system containing OR-PAM and OCT offered a fine lateral resolution of ∼5 μm and a penetration depth of ∼1 mm into the scaffold/tissue construct. AR-PAM further extended the penetration depth up to ∼3 mm at a lateral resolution of ∼45 μm. By quantifying the 3D PAM data, we further examined the effect of pore size (200 vs. 80 μm) of a scaffold on neovascularization. The data collected from PAM were consistent with those obtained from traditional invasive, labor-intensive histologic analyses.
AB - It is a grand challenge to visualize and assess in vivo neovascularization in a three-dimensional (3D) scaffold noninvasively, together with high spatial resolution and deep penetration depth. Here we used multiscale photoacoustic microscopy (PAM), including acoustic-resolution PAM (AR-PAM) and optical-resolution PAM (OR-PAM), to chronically monitor neovascularization in an inverse opal scaffold implanted in a mouse model up to 6 weeks by taking advantage of the optical absorption contrast intrinsic to hemoglobin molecules in red blood cells. By combining with optical coherence tomography (OCT) based on optical scattering contrast, we also demonstrated the capability to simultaneously image and analyze the vasculature and the scaffold in the same mouse. The hybrid system containing OR-PAM and OCT offered a fine lateral resolution of ∼5 μm and a penetration depth of ∼1 mm into the scaffold/tissue construct. AR-PAM further extended the penetration depth up to ∼3 mm at a lateral resolution of ∼45 μm. By quantifying the 3D PAM data, we further examined the effect of pore size (200 vs. 80 μm) of a scaffold on neovascularization. The data collected from PAM were consistent with those obtained from traditional invasive, labor-intensive histologic analyses.
UR - http://www.scopus.com/inward/record.url?scp=84873853755&partnerID=8YFLogxK
U2 - 10.1089/ten.tec.2012.0326
DO - 10.1089/ten.tec.2012.0326
M3 - Article
C2 - 22838500
AN - SCOPUS:84873853755
SN - 1937-3384
VL - 19
SP - 196
EP - 204
JO - Tissue Engineering - Part C: Methods
JF - Tissue Engineering - Part C: Methods
IS - 3
ER -