TY - JOUR
T1 - Intrasequence GFP in class I MHC molecules, a rigid probe for fluorescence anisotropy measurements of the membrane environment
AU - Rocheleau, Jonathan V.
AU - Edidin, Michael
AU - Piston, David W.
N1 - Funding Information:
This work was supported by National Institutes of Health grants DK53434 and CA86283 to D.W.P., and AI-14584 to M.E.; and a National Science Foundation grant DBI-9871063 to D.W.P. A National Institutes of Health Individual National Research Service Award, DK59737, also supported J.V.R. Steady-state anisotropy imaging was performed, in part, through the use of the Vanderbilt University Medical Center Cell Imaging Core Resource, which is supported by National Institutes of Health grants CA68485 and DK20593.
PY - 2003/6/1
Y1 - 2003/6/1
N2 - Fluorescence anisotropy measurements can elucidate the microenvironment of a membrane protein in terms of its rotational diffusion, interactions, and proximity to other proteins. However, use of this approach requires a fluorescent probe that is rigidly attached to the protein of interest. Here we describe the use of one such probe, a green fluorescent protein (GFP) expressed and rigidly held within the amino acid sequence of a major histocompatibility complex (MHC) class I molecule, H2Ld. We contrast the anisotropy of this GFP-tagged MHC molecule, H2LdGFPout, with that of an H2Ld that was GFP-tagged at its C-terminus, H2LdGFPin. Both molecules fold properly, reach the cell surface, and are recognized by specific antibodies and T-cell receptors. We found that polarized fluorescence images of H2LdGFPout in plasma membrane blebs show intensity variations that depend on the relative orientation of the polarizers and the membrane normal, thus demonstrating that the GFP is oriented with respect to the membrane. These variations were not seen for H2LdGFPin. Before transport to the membrane surface, MHC class I associates with the transporter associated with antigen processing complex in the endoplasmic reticulum. The intensity-dependent steady-state anisotropy in the ER of H2LdGFPout was consistent with FRET homotransfer, which indicates that a significant fraction of these molecules were clustered. After MCMV-peptide loading, which supplies antigenic peptide to the MHC class I releasing it from the antigen processing complex, the anisotropy of H2LdGFPout was independent of intensity, suggesting that the MHC proteins were no longer clustered. These results demonstrate the feasibility and usefulness of a GFP moiety rigidly attached to the protein of interest as a probe for molecular motion and proximity in cell membranes.
AB - Fluorescence anisotropy measurements can elucidate the microenvironment of a membrane protein in terms of its rotational diffusion, interactions, and proximity to other proteins. However, use of this approach requires a fluorescent probe that is rigidly attached to the protein of interest. Here we describe the use of one such probe, a green fluorescent protein (GFP) expressed and rigidly held within the amino acid sequence of a major histocompatibility complex (MHC) class I molecule, H2Ld. We contrast the anisotropy of this GFP-tagged MHC molecule, H2LdGFPout, with that of an H2Ld that was GFP-tagged at its C-terminus, H2LdGFPin. Both molecules fold properly, reach the cell surface, and are recognized by specific antibodies and T-cell receptors. We found that polarized fluorescence images of H2LdGFPout in plasma membrane blebs show intensity variations that depend on the relative orientation of the polarizers and the membrane normal, thus demonstrating that the GFP is oriented with respect to the membrane. These variations were not seen for H2LdGFPin. Before transport to the membrane surface, MHC class I associates with the transporter associated with antigen processing complex in the endoplasmic reticulum. The intensity-dependent steady-state anisotropy in the ER of H2LdGFPout was consistent with FRET homotransfer, which indicates that a significant fraction of these molecules were clustered. After MCMV-peptide loading, which supplies antigenic peptide to the MHC class I releasing it from the antigen processing complex, the anisotropy of H2LdGFPout was independent of intensity, suggesting that the MHC proteins were no longer clustered. These results demonstrate the feasibility and usefulness of a GFP moiety rigidly attached to the protein of interest as a probe for molecular motion and proximity in cell membranes.
UR - https://www.scopus.com/pages/publications/0037763890
U2 - 10.1016/S0006-3495(03)75133-9
DO - 10.1016/S0006-3495(03)75133-9
M3 - Article
C2 - 12770911
AN - SCOPUS:0037763890
SN - 0006-3495
VL - 84
SP - 4078
EP - 4086
JO - Biophysical Journal
JF - Biophysical Journal
IS - 6
ER -