TY - JOUR
T1 - Interruption of CGM
T2 - Frequency and Adverse Consequences
AU - Markov, Alexander M.
AU - Krutilova, Petra
AU - Cedeno, Andrea E.
AU - McGill, Janet
AU - McKee, Alexis M.
N1 - Funding Information:
The author(s) declared no potential conflicts of interest with respect to the research, authorship, and/or publication of this article. A.M.M. has participated on advisory boards for Medtronic Inc and Novo Nordisk. J.B.M. has served on consulting and advisory boards for Bayer, Boehringer Ingelheim, MannKind, Novo Nordisk, and Thermo Fisher and received grant support from Beta Bionics, Medtronic Inc, NIH, Novo Nordisk, and JDRF. Other authors have no conflicts of interest to disclose.
Publisher Copyright:
© 2023 Diabetes Technology Society.
PY - 2023
Y1 - 2023
N2 - Background: Removal of diabetes devices, including insulin pumps and continuous glucose monitoring (CGM), is a common practice due to hospital policies, interference with imaging studies, medications, and surgical interventions. Furthermore, these devices are inherently prone to malfunction, adhesive failure, and issues with insertion that can lead to a reduction in wear time. Prescription and dispensing practices provide an exact number of sensors per month without redundancy to account for the realities of daily CGM use. Methods: A RedCap survey was completed by adult patients with type 1 or type 2 diabetes (T1D or T2D) who utilize CGM followed in the Diabetes Center at Washington University in St Louis. Results: Of 384 surveys sent, 99 were completed. Participants had a mean age of 54 years, T1D 69%, female 70%, White 96%, non-Hispanic 96%, and a mean duration of diabetes mellitus (DM) 28 years. Of the cohort, 100% used CGM (80.2% Dexcom, 13.5% Freestyle Libre, 6.3% Medtronic), 61% insulin pump, and 41% Hybrid closed-loop (HCL) systems. CGM-related disruption events included device malfunction (in 85.4% of participants), insertion problems (63.5%), and falling off (61.4%). Medical care–related disruption occurred most frequently in the setting of imaging (41.7%), followed by surgery/procedures (11.7%) and hospitalization (4.4%). Adverse glycemic events attributed to CGM disruption, including hyperglycemia and hypoglycemia, occurred ≥4 times in 36.5% and 12.4% of the cohort, respectively. Conclusions: Disruption in CGM use is common. Lack of redundancy of CGM supplies contributes to care disruption and adverse glycemic events.
AB - Background: Removal of diabetes devices, including insulin pumps and continuous glucose monitoring (CGM), is a common practice due to hospital policies, interference with imaging studies, medications, and surgical interventions. Furthermore, these devices are inherently prone to malfunction, adhesive failure, and issues with insertion that can lead to a reduction in wear time. Prescription and dispensing practices provide an exact number of sensors per month without redundancy to account for the realities of daily CGM use. Methods: A RedCap survey was completed by adult patients with type 1 or type 2 diabetes (T1D or T2D) who utilize CGM followed in the Diabetes Center at Washington University in St Louis. Results: Of 384 surveys sent, 99 were completed. Participants had a mean age of 54 years, T1D 69%, female 70%, White 96%, non-Hispanic 96%, and a mean duration of diabetes mellitus (DM) 28 years. Of the cohort, 100% used CGM (80.2% Dexcom, 13.5% Freestyle Libre, 6.3% Medtronic), 61% insulin pump, and 41% Hybrid closed-loop (HCL) systems. CGM-related disruption events included device malfunction (in 85.4% of participants), insertion problems (63.5%), and falling off (61.4%). Medical care–related disruption occurred most frequently in the setting of imaging (41.7%), followed by surgery/procedures (11.7%) and hospitalization (4.4%). Adverse glycemic events attributed to CGM disruption, including hyperglycemia and hypoglycemia, occurred ≥4 times in 36.5% and 12.4% of the cohort, respectively. Conclusions: Disruption in CGM use is common. Lack of redundancy of CGM supplies contributes to care disruption and adverse glycemic events.
KW - continuous glucose monitoring
KW - device disruption
KW - diabetes technology
KW - wear time
UR - http://www.scopus.com/inward/record.url?scp=85148738089&partnerID=8YFLogxK
U2 - 10.1177/19322968231156572
DO - 10.1177/19322968231156572
M3 - Article
C2 - 36824046
AN - SCOPUS:85148738089
SN - 1932-2968
JO - Journal of Diabetes Science and Technology
JF - Journal of Diabetes Science and Technology
ER -