N2 - Objectives: To evaluate short- and middle-term outcomes after transcatheter patent ductus arteriosus (TC-PDA) closure in small infants, specifically device-related left pulmonary artery (LPA) stenosis and aortic coarctation, risk factors, and changes over time. Background: Recent studies have demonstrated successful transcatheter PDA (TC-PDA) closure in small infants. LPA stenosis and aortic coarctation have been seen after TC-PDA, but it is not clear whether device-related LPA/aortic obstruction persists. Methods: A single-center retrospective study of infants ≤4 kg who underwent TC-PDA closure from February 1, 2007 to September 1, 2018 was performed, evaluating the incidence and risk factors for LPA stenosis and coarctation. Results: Forty-four patients underwent successful TC-PDA with Amplatzer Vascular Plug II (AVPII; n = 30), Amplatzer Duct Occluder II-Additional Sizes (n = 10), Amplatzer Duct Occluder I (n = 3), and coil-filled AVPI (n = 1) devices, all via an antegrade approach. Median birthweight and procedural weight were 890 g (range: 490–3,250) and 2.8 kg (range: 1.2–4.0), respectively. Median follow-up was 0.7 years (range: 2 days–7 years). Thirty-eight patients had post-procedure echocardiograms assessing LPA/aortic obstruction. Of those, 17 had LPA flow acceleration/stenosis (≥1.5 m/s), which improved or resolved in all patients with available follow-up; 3 developed mild coarctation (>2 m/s), which improved in the two with more than short-term follow-up; 4 developed mild flow acceleration (1.5–2 m/s) in the descending aorta, which resolved in three and increased in one (2.4 m/s). Flow acceleration in the LPA was associated with younger procedural age, larger PDA minimal diameter, and placement of a device other than the AVPII. There was no device-related mortality or need for reintervention. Conclusion: TC-PDA in small infants is effective, without significant complications. Device-related LPA/aortic obstruction can improve with time/growth.
AB - Objectives: To evaluate short- and middle-term outcomes after transcatheter patent ductus arteriosus (TC-PDA) closure in small infants, specifically device-related left pulmonary artery (LPA) stenosis and aortic coarctation, risk factors, and changes over time. Background: Recent studies have demonstrated successful transcatheter PDA (TC-PDA) closure in small infants. LPA stenosis and aortic coarctation have been seen after TC-PDA, but it is not clear whether device-related LPA/aortic obstruction persists. Methods: A single-center retrospective study of infants ≤4 kg who underwent TC-PDA closure from February 1, 2007 to September 1, 2018 was performed, evaluating the incidence and risk factors for LPA stenosis and coarctation. Results: Forty-four patients underwent successful TC-PDA with Amplatzer Vascular Plug II (AVPII; n = 30), Amplatzer Duct Occluder II-Additional Sizes (n = 10), Amplatzer Duct Occluder I (n = 3), and coil-filled AVPI (n = 1) devices, all via an antegrade approach. Median birthweight and procedural weight were 890 g (range: 490–3,250) and 2.8 kg (range: 1.2–4.0), respectively. Median follow-up was 0.7 years (range: 2 days–7 years). Thirty-eight patients had post-procedure echocardiograms assessing LPA/aortic obstruction. Of those, 17 had LPA flow acceleration/stenosis (≥1.5 m/s), which improved or resolved in all patients with available follow-up; 3 developed mild coarctation (>2 m/s), which improved in the two with more than short-term follow-up; 4 developed mild flow acceleration (1.5–2 m/s) in the descending aorta, which resolved in three and increased in one (2.4 m/s). Flow acceleration in the LPA was associated with younger procedural age, larger PDA minimal diameter, and placement of a device other than the AVPII. There was no device-related mortality or need for reintervention. Conclusion: TC-PDA in small infants is effective, without significant complications. Device-related LPA/aortic obstruction can improve with time/growth.
KW - catheterization
KW - congenital heart disease
KW - percutaneous
KW - premature
UR - http://www.scopus.com/inward/record.url?scp=85084118846&partnerID=8YFLogxK
U2 - 10.1002/ccd.28942
DO - 10.1002/ccd.28942
M3 - Article
C2 - 32339400
AN - SCOPUS:85084118846
SN - 1522-1946
VL - 96
SP - 889
EP - 897
JO - Catheterization and Cardiovascular Interventions
JF - Catheterization and Cardiovascular Interventions
IS - 4
ER -