TY - JOUR
T1 - Improving the Signal Intensity and Sensitivity of MALDI Mass Spectrometry by Using Nanoliter Spots Deposited by Induction-Based Fluidics
AU - Tu, Tingting
AU - Sauter, Andrew D.
AU - Sauter, Andrew D.
AU - Gross, Michael L.
N1 - Funding Information:
This research was supported by National Center for Research Resources of the National Institutes of Health Grant 2P41-RR-00594. The authors thank Dr. John Koomen (Moffitt Cancer Center) for valuable suggestions to improve the revision.
PY - 2008/8
Y1 - 2008/8
N2 - A new contact-free, small droplet deposition method using an induction-based fluidics (IBF) technique to dispense nanoliter drops is described and evaluated for sample preparation in matrix-assisted laser desorption ionization mass spectrometry (MALDI-MS). The signal intensities available when using nanoliter spots are greater than those obtained with normal, microliter spots when the same amount of analyte is used. When using an ionic-liquid matrix, the improvement in sensitivity is equal to the concentration enhancement that was achieved by using smaller quantities of matrix. When using a conventional solid matrix, however, the increase in signal intensity shows a more complicated relationship to concentration. The approach of nanoliter deposition also supports multiple spotting to increase sample concentration and, thus, sample signal intensity. Nanoliter spotting not only improves the signal intensity and sensitivity achieved by MALDI-MS but also allows a major fraction of trace samples to be saved for other experiments, thus expanding the application of MALDI-MS to biological studies where sample quantity is limited.
AB - A new contact-free, small droplet deposition method using an induction-based fluidics (IBF) technique to dispense nanoliter drops is described and evaluated for sample preparation in matrix-assisted laser desorption ionization mass spectrometry (MALDI-MS). The signal intensities available when using nanoliter spots are greater than those obtained with normal, microliter spots when the same amount of analyte is used. When using an ionic-liquid matrix, the improvement in sensitivity is equal to the concentration enhancement that was achieved by using smaller quantities of matrix. When using a conventional solid matrix, however, the increase in signal intensity shows a more complicated relationship to concentration. The approach of nanoliter deposition also supports multiple spotting to increase sample concentration and, thus, sample signal intensity. Nanoliter spotting not only improves the signal intensity and sensitivity achieved by MALDI-MS but also allows a major fraction of trace samples to be saved for other experiments, thus expanding the application of MALDI-MS to biological studies where sample quantity is limited.
UR - http://www.scopus.com/inward/record.url?scp=48349135634&partnerID=8YFLogxK
U2 - 10.1016/j.jasms.2008.03.017
DO - 10.1016/j.jasms.2008.03.017
M3 - Article
C2 - 18479933
AN - SCOPUS:48349135634
SN - 1044-0305
VL - 19
SP - 1086
EP - 1090
JO - Journal of the American Society for Mass Spectrometry
JF - Journal of the American Society for Mass Spectrometry
IS - 8
ER -