TY - GEN
T1 - Impact of water chemistry on the formation, stabilization, and dissolution rates of Pb(IV) oxides
AU - Xie, Yanjiao
AU - Noel, James D.
AU - Nelson, Katherine
AU - Giammar, Daniel E.
PY - 2008
Y1 - 2008
N2 - Lead can be released to drinking water from corrosion and dissolution of leadcontaining pipes, fittings and solders in existing old drinking water service lines. Resulting high lead concentrations can cause adverse health effects. Pb(II) solids and Pb(IV) oxides, discovered as the corrosion products covering the walls of lead pipes, are the major contributors to lead release. Among them, Pb(II) solids are presumed to have higher solubility relative to Pb(IV) oxides. Thus, switching the residual disinfection method from chlorine to chloramines can lower the oxidation-reduction potential (ORP), thereby enabling the breakdown of Pb(IV) oxides and consequently higher lead concentration. However, there is limited data on the equilibrium solubility or dissolution and transformation rates of Pb(IV) oxides. Also, substantial research on the water chemistry conditions in which Pb(IV) oxides form and stabilize over time is needed for a scientific strategy of controlling lead concentration in drinking water distribution systems. In our research, the equilibrium solubility, dissolution and transformation rates of pure Pb(IV) oxides are investigated as a function of pH, dissolved inorganic carbon (DIC), orthophosphate, and the presence of chloramines. New lead pipes are conditioned using chlorine to form Pb(IV) oxides, and release rates of lead from them are investigated under varied water chemistry, stagnation time and flow velocity. The lead corrosion products and possible transformation of them are characterized with respect to mineralogy, size, morphology, surface area, and molecular structure. Water chemistry conditions, including pH, ORP in terms of chlorine concentration, lead concentration and DIC, in which α-PbO2 and β-PbO 2 form and stabilize over time are also studied.
AB - Lead can be released to drinking water from corrosion and dissolution of leadcontaining pipes, fittings and solders in existing old drinking water service lines. Resulting high lead concentrations can cause adverse health effects. Pb(II) solids and Pb(IV) oxides, discovered as the corrosion products covering the walls of lead pipes, are the major contributors to lead release. Among them, Pb(II) solids are presumed to have higher solubility relative to Pb(IV) oxides. Thus, switching the residual disinfection method from chlorine to chloramines can lower the oxidation-reduction potential (ORP), thereby enabling the breakdown of Pb(IV) oxides and consequently higher lead concentration. However, there is limited data on the equilibrium solubility or dissolution and transformation rates of Pb(IV) oxides. Also, substantial research on the water chemistry conditions in which Pb(IV) oxides form and stabilize over time is needed for a scientific strategy of controlling lead concentration in drinking water distribution systems. In our research, the equilibrium solubility, dissolution and transformation rates of pure Pb(IV) oxides are investigated as a function of pH, dissolved inorganic carbon (DIC), orthophosphate, and the presence of chloramines. New lead pipes are conditioned using chlorine to form Pb(IV) oxides, and release rates of lead from them are investigated under varied water chemistry, stagnation time and flow velocity. The lead corrosion products and possible transformation of them are characterized with respect to mineralogy, size, morphology, surface area, and molecular structure. Water chemistry conditions, including pH, ORP in terms of chlorine concentration, lead concentration and DIC, in which α-PbO2 and β-PbO 2 form and stabilize over time are also studied.
UR - https://www.scopus.com/pages/publications/84871593993
M3 - Conference contribution
AN - SCOPUS:84871593993
SN - 9781605609935
T3 - Water Quality Technology Conference and Exposition 2008
SP - 596
EP - 606
BT - Water Quality Technology Conference and Exposition 2008
T2 - Water Quality Technology Conference and Exposition 2008
Y2 - 16 November 2008 through 20 November 2008
ER -