TY - JOUR
T1 - Impact of appropriate use on the prognostic value of single-photon emission computed tomography myocardial perfusion imaging
AU - Doukky, Rami
AU - Hayes, Kathleen
AU - Frogge, Nathan
AU - Balakrishnan, Gautam
AU - Dontaraju, Venkata Satish
AU - Rangel, Maria O.
AU - Golzar, Yasmeen
AU - Garcia-Sayan, Enrique
AU - Hendel, Robert C.
PY - 2013/10/8
Y1 - 2013/10/8
N2 - BACKGROUND - Appropriate use criteria (AUC) have been developed to aid in the optimal use of single-photon emission computed tomography (SPECT)-myocardial perfusion imaging (MPI), a technique that is a mainstay of risk assessment for ischemic heart disease. The impact of appropriate use on the prognostic value of SPECT-MPI is unknown. METHODS AND RESULTS - A prospective cohort study of 1511 consecutive patients undergoing outpatient, community-based SPECT-MPI was conducted. Subjects were stratified on the basis of the 2009 AUC for SPECT-MPI into an appropriate or uncertain appropriateness group and an inappropriate group. Patients were prospectively followed up for 27±10 months for major adverse cardiac events of death, death or myocardial infarction, and cardiac death or myocardial infarction. In the entire cohort, the 167 subjects (11%) with an abnormal scan experienced significantly higher rates of major adverse cardiac events and coronary revascularization than those with normal MPI. Among the 823 subjects (54.5%) whose MPIs were classified as appropriate (779, 51.6%) or uncertain (44, 2.9%), an abnormal scan predicted a multifold increase in the rates of death (9.2% versus 2.6%; hazard ratio, 3.1; P=0.004), death or myocardial infarction (11.8% versus 3.3%; hazard ratio, 3.3; P=0.001), cardiac death or myocardial infarction (6.7% versus 1.7%; hazard ratio, 3.7; P=0.006), and revascularization (24.7% versus 2.7%; hazard ratio, 11.4; P<0.001). Among the 688 subjects (45.5%) with MPI classified as inappropriate, an abnormal MPI failed to predict major adverse cardiac events, although it was associated with a high revascularization rate. Furthermore, appropriate MPI use provided incremental prognostic value beyond myocardial perfusion and ejection fraction data. CONCLUSIONS - When performed for appropriate indications, SPECT-MPI continues to demonstrate high prognostic value. However, inappropriate use lacks effectiveness for risk stratification, further emphasizing the need for optimal patient selection for cardiac testing.
AB - BACKGROUND - Appropriate use criteria (AUC) have been developed to aid in the optimal use of single-photon emission computed tomography (SPECT)-myocardial perfusion imaging (MPI), a technique that is a mainstay of risk assessment for ischemic heart disease. The impact of appropriate use on the prognostic value of SPECT-MPI is unknown. METHODS AND RESULTS - A prospective cohort study of 1511 consecutive patients undergoing outpatient, community-based SPECT-MPI was conducted. Subjects were stratified on the basis of the 2009 AUC for SPECT-MPI into an appropriate or uncertain appropriateness group and an inappropriate group. Patients were prospectively followed up for 27±10 months for major adverse cardiac events of death, death or myocardial infarction, and cardiac death or myocardial infarction. In the entire cohort, the 167 subjects (11%) with an abnormal scan experienced significantly higher rates of major adverse cardiac events and coronary revascularization than those with normal MPI. Among the 823 subjects (54.5%) whose MPIs were classified as appropriate (779, 51.6%) or uncertain (44, 2.9%), an abnormal scan predicted a multifold increase in the rates of death (9.2% versus 2.6%; hazard ratio, 3.1; P=0.004), death or myocardial infarction (11.8% versus 3.3%; hazard ratio, 3.3; P=0.001), cardiac death or myocardial infarction (6.7% versus 1.7%; hazard ratio, 3.7; P=0.006), and revascularization (24.7% versus 2.7%; hazard ratio, 11.4; P<0.001). Among the 688 subjects (45.5%) with MPI classified as inappropriate, an abnormal MPI failed to predict major adverse cardiac events, although it was associated with a high revascularization rate. Furthermore, appropriate MPI use provided incremental prognostic value beyond myocardial perfusion and ejection fraction data. CONCLUSIONS - When performed for appropriate indications, SPECT-MPI continues to demonstrate high prognostic value. However, inappropriate use lacks effectiveness for risk stratification, further emphasizing the need for optimal patient selection for cardiac testing.
KW - Myocardial perfusion imaging
KW - Outcome assessment (health care)
KW - Prognosis
KW - Tomography, emission-computed, single-photon
UR - https://www.scopus.com/pages/publications/84885834370
U2 - 10.1161/CIRCULATIONAHA.113.002744
DO - 10.1161/CIRCULATIONAHA.113.002744
M3 - Article
C2 - 24021779
AN - SCOPUS:84885834370
SN - 0009-7322
VL - 128
SP - 1634
EP - 1643
JO - Circulation
JF - Circulation
IS - 15
ER -